Vergleichsstudie in der Zeitschrift Stereotactic and Functional Neurosurgery, 2025. Verfasst von Jorge Gonzalez Martinez und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA, jic368@pitt.edu. Hauptthemen laut MEDLINE: Electroencephalography, Stereotaxic Techniques, Electrodes, Implanted, Device Removal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Stereotactic electroencephalography (SEEG) involves the implantation of intracortical electrodes for the precise localization of the epileptogenic zone and is well-established in terms of its safety and efficacy during implantation; however, there is a notable lack of research comparing different electrode removal techniques, specifically regarding complications and feasibility of these approaches. This study evaluates the feasibility and clinical utility of intraoperative versus extraoperative (bedside) removal of stereotactic electroencephalography (SEEG) electrodes.

Methods

The early feasibility study retrospectively reviewed 117 consecutive SEEG patients at our institution, comparing 101 intraoperative cases with 16 extraoperative cases. A total of 1,624 SEEG electrodes were evaluated. Results related to demographics, feasibility of bedside removal, and occurrence of complications were analyzed and statistically compared between groups.

Results

Our findings reveal comparable patient demographics across both groups and demonstrate low complication rates of 1.98% for intraoperative and 0.00% for extraoperative removals, with a combined rate of 1.71%. Importantly, zero cases of infection were observed in both settings. In addition to the low rates of complication in both the intraoperative and extraoperative explant groups, the study indicates a statistically significantly reduced use of sedation in the extraoperative group, which may enhance patient comfort and eliminate the need for additional sedatives during their ongoing treatment. The extraoperative bedside approach also offers practical benefits, such as removing the need for operating room (OR) resources and staffing, which can prevent OR delays and contribute to shorter hospital stays.

Conclusion

With the appropriate indications, the extraoperative removal of SEEG electrodes appears to be a feasible and safe alternative to the intraoperative method. It presents potential advantages in optimizing patient flow within epilepsy monitoring units, improving operational efficiency, and potentially reducing healthcare costs while promoting patient comfort. Future research is essential to validate these findings further and refine the bedside technique for broader clinical application.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyStereotaxic TechniquesElectrodes, ImplantedDevice RemovalPostoperative ComplicationsEpilepsyHumansFemaleMaleFeasibility StudiesAdultRetrospective StudiesMiddle AgedYoung AdultAdolescentChild

Stichwörter der Autor:innen

Epilepsy surgeryOperative complicationStereo-electroencephalography

Autor:innen und Institutionen

  • Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA, jic368@pitt.edu.
  • Department of Neurology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA, jic368@pitt.edu.
  • Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
  • Department of Neurology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.

Zitieren

APA

Gonzalez Martinez, J., Chen, J. J., Aung, T., Constantine, T., & Gonzalez-Martinez, J. A. (2025). Comparative Feasibility and Complication Analyses of Extraoperative (Bedside) Removal of Stereo-Electroencephalography Electrodes. Stereotactic and Functional Neurosurgery. https://doi.org/10.1159/000545984

Vancouver

Gonzalez Martinez J, Chen JJ, Aung T, Constantine T, Gonzalez-Martinez JA. Comparative Feasibility and Complication Analyses of Extraoperative (Bedside) Removal of Stereo-Electroencephalography Electrodes. Stereotactic and Functional Neurosurgery. 2025. doi:10.1159/000545984

BibTeX
@article{GonzalezMartinez2025,
  author = {Gonzalez Martinez, Jorge and Chen, Jiahao J and Aung, Thandar and Constantine, Theodora and Gonzalez-Martinez, Jorge Alvaro},
  title = {Comparative Feasibility and Complication Analyses of Extraoperative (Bedside) Removal of Stereo-Electroencephalography Electrodes},
  journal = {Stereotactic and Functional Neurosurgery},
  year = {2025},
  doi = {10.1159/000545984}
}
Kostenlos starten →