EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

One-Hour Troponin Using a High-Sensitivity Point-of-Care Assay in Emergency Primary Care: The OUT-POC Pilot Study

Tonje R Johannessen, Odd Martin Vallersnes, Anne Cecilie K Larstorp, Sigrun Halvorsen, Dan Atar

Cardiology · 2025

DOI: 10.1159/000545127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiology, 2025. Verfasst von Tonje R Johannessen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Practice, University of Oslo, Oslo, Norway, t.r.johannessen@medisin.uio.no. Hauptthemen laut MEDLINE: Myocardial Infarction, Troponin I, Point-of-Care Systems, Troponin T. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Novel point-of-care (POC) high-sensitivity cardiac troponin (hs-cTn) tests could enhance acute myocardial infarction (MI) assessment outside hospital. This pilot study evaluates the efficacy, feasibility, and precision of the QuidelOrtho TriageTrue hs-cTnI POC assay when used by non-laboratory personnel in emergency primary care.

Methods

A prospective pilot study was conducted from April to June 2024 at the main emergency primary care clinic in Oslo, Norway. Patients ≥18 years with acute nontraumatic chest pain were eligible. The 0/1-h diagnostic algorithms for the POC TriageTrue hs-cTnI and the Roche Elecsys hs-cTnT central laboratory assay (routine protocol) were compared to assess the efficacy and potential safety issues for patients triaged to MI rule-out.

Results

Over 2 months, 199 patients (median age 54 years [interquartile range 45–70]; 52.8% female) were included. Five (2.5%) patients were hospitalised with acute MI. After a single hs-cTnI measurement, the POC algorithm categorised more patients to direct rule-out than the hs-cTnT assay (65% vs. 32%). The rule-out efficacy was similar for both assays after adding the 1-hour measurement (hs-cTnT 74%; POC hs-cTnI 73%). Device-related error rates were low (0.5%), with high reproducibility and repeatability (coefficients of variation < 10%) when performed by non-laboratory personnel.

Conclusion

The 0/1-h algorithm for the TriageTrue hs-cTnI POC assay appears efficient, feasible, and robust when applied by personnel without laboratory expertise in an emergency primary care setting. Further research is warranted, but given the high proportion of single-sample rule-out cases, 1-h measurements could likely be avoided, improving patient management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial InfarctionTroponin IPoint-of-Care SystemsTroponin TPoint-of-Care TestingHumansPilot ProjectsMiddle AgedFemaleMaleProspective StudiesAgedPrimary Health CareNorwayBiomarkersEmergency Medical ServicesAlgorithmsTriageChest PainFeasibility Studies

Stichwörter der Autor:innen

Acute myocardial infarctionChest painHigh-sensitivity cardiac troponinPoint-of-care testingPrimary care

Substanzen

Troponin IBiomarkersTroponin T

Autor:innen und Institutionen

  • Department of General Practice, University of Oslo, Oslo, Norway, t.r.johannessen@medisin.uio.no.
  • Department of Emergency General Practice, Oslo Accident Emergency Outpatient Clinic, City of Oslo Health Agency, Oslo, Norway, t.r.johannessen@medisin.uio.no.
  • Department of General Practice, University of Oslo, Oslo, Norway.
  • Department of Emergency General Practice, Oslo Accident Emergency Outpatient Clinic, City of Oslo Health Agency, Oslo, Norway.
  • Department of Medical Biochemistry and Section for Cardiovascular and Renal Research, Oslo University Hospital, Oslo, Norway.
  • Institute of Clinical Medicine, University of Oslo, Oslo, Norway.

Zitieren

APA

Johannessen, T. R., Vallersnes, O. M., Larstorp, A. C. K., Halvorsen, S., & Atar, D. (2025). One-Hour Troponin Using a High-Sensitivity Point-of-Care Assay in Emergency Primary Care: The OUT-POC Pilot Study. Cardiology. https://doi.org/10.1159/000545127

Vancouver

Johannessen TR, Vallersnes OM, Larstorp ACK, Halvorsen S, Atar D. One-Hour Troponin Using a High-Sensitivity Point-of-Care Assay in Emergency Primary Care: The OUT-POC Pilot Study. Cardiology. 2025. doi:10.1159/000545127

BibTeX
@article{Johannessen2025,
  author = {Johannessen, Tonje R and Vallersnes, Odd Martin and Larstorp, Anne Cecilie K and Halvorsen, Sigrun and Atar, Dan},
  title = {One-Hour Troponin Using a High-Sensitivity Point-of-Care Assay in Emergency Primary Care: The OUT-POC Pilot Study},
  journal = {Cardiology},
  year = {2025},
  doi = {10.1159/000545127}
}
Kostenlos starten →