Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Neuroendocrine Tumors with Rapid On-Site Evaluation: Single-Center Experience
Acta Cytologica · 2024
DOI: 10.1159/000543364 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Cytologica, 2024. Verfasst von Irem Guvendir Bakkaloglu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Pathology Department, Kartal Dr. Lutfi Kirdar City Hospital, Istanbul, Turkey. Hauptthemen laut MEDLINE: Pancreatic Neoplasms, Endoscopic Ultrasound-Guided Fine Needle Aspiration, Neuroendocrine Tumors. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
Introduction
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a highly sensitive and accurate method for identifying pancreatic neuroendocrine tumors (PanNETs). However, research on grading and assessing the Ki67 proliferation index in FNA samples is limited.
Methods
This study analyzed 335 EUS-FNA cases performed between 2016 and 2022, of which 12 cases of PanNET were further evaluated. The morphology, Ki-67 index, and grading (G) of cell blocks (CBs) obtained from the PanNET aspirations were compared to those of the resected material.
Results
Out of 12 PanNET’s with rapid on-site evaluation (ROSE), in FNA samples and CB, 7 (58.3%) cases were G1, while 5 (41.7%) cases were G2. On the other hand, on resection of these cases, 6 (50%) were diagnosed as G1, 5 (41.7%) cases were G2, and 1 case (8.3%) was G3. The average Ki-67 index in CB was 2.92 (min: 1 – max: 10), while in resections it was 4.67 (min: 1 – max: 22). Only 2 (16.6%) showed a discordance between grade and Ki-67, resulting in an overall concordance of over 80%. On average, 1.83 needle passes were made (range: 1–3), while the average number of slides and CBs were 9.33 (range: 1–24) and 2.17 (range: 1–6), respectively. There were no significant differences in the number of passes, slides, or CBs between the consistent and discordant groups.
Conclusion
Optimal counting techniques and sensitivity for Ki67 are crucial in grading PanNETs in both aspiration and resection materials. The grade and Ki-67 index demonstrated high concordance when comparing CB and resection. However, in low-volume centers, ROSE support can be beneficial in obtaining sufficient slides and CB for an adequate diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Pathology Department, Kartal Dr. Lutfi Kirdar City Hospital, Istanbul, Turkey.
- Pathology Department, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
- Pathology Department, Health Sciences University, Umraniye Training and Research Hospital, Istanbul, Turkey.
Zitieren
APA
Bakkaloglu, I. G., Gurbuz, B. C., Sahin, O., & Zemheri, I. E. (2024). Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Neuroendocrine Tumors with Rapid On-Site Evaluation: Single-Center Experience. Acta Cytologica. https://doi.org/10.1159/000543364
Vancouver
Bakkaloglu IG, Gurbuz BC, Sahin O, Zemheri IE. Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Neuroendocrine Tumors with Rapid On-Site Evaluation: Single-Center Experience. Acta Cytologica. 2024. doi:10.1159/000543364
BibTeX
@article{Bakkaloglu2024,
author = {Bakkaloglu, Irem Guvendir and Gurbuz, Begum Calim and Sahin, Onur and Zemheri, Itir Ebru},
title = {Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Neuroendocrine Tumors with Rapid On-Site Evaluation: Single-Center Experience},
journal = {Acta Cytologica},
year = {2024},
doi = {10.1159/000543364}
}
EUVIMED