Adverse Events Associated with Surgically Implanted Temporomandibular Joint Devices
ORL · 2025
DOI: 10.1159/000543243 ↗Kurz gefasst
Fachartikel in der Zeitschrift ORL, 2025. Verfasst von Christian Fritz und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology - Head and Neck Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Temporomandibular Joint Disorders, Postoperative Complications, Joint Prosthesis, Temporomandibular Joint. Die Arbeit nennt 29 Literaturangaben.
Themen: Patientensicherheit
Abstract (Originalsprache)
Introduction
Temporomandibular disorder (TMD) is a common, yet potentially debilitating syndrome that negatively impacts patient quality of life. In patients with severe variants of TMD, temporomandibular joint (TMJ) devices have been utilized to replace the joint altogether. However, the risk profile and consequent cost-benefit ratio of these devices are largely debated. This report aimed to provide further insight on the safety of surgically implanted TMJ devices by analyzing adverse events from the Manufacturer and User Facility Device Experience (MAUDE) database.
Methods
Inclusion criteria consisted of all MAUDE reports from January 2013 to January 2023 containing the keyword “TMJ.” Duplicate reports, preimplantation events, reports extrapolated from published literature reviews, and those not related to TMJ implants were excluded from analysis. Adverse events were extracted, reviewed, and categorized according to complication type, management strategy, device manufacturer, causes of device malfunction, and reporting timeframe. Nonparametric χ2 and Levene’s test were used to compare average values between groups with a two-tailed p value of 0.05 being considered statistically significant.
Results
A total of 385 adverse event reports were reviewed. The most common complications were infection (59, 25.9%), ankylosis (57, 25.0%), and pain (33, 14.5%). The most common device failures were implant malposition (28, 39.4%), implant dislodgement (22, 31.0%), and screw osseointegration failure (11, 15.5%). Upon assessment of revision surgeries, those undertaken to address infections had the highest rate of device explantation (77%). In a separate analysis of 28 adverse events submitted directly by patients, infection was most common self-reported complication (42.9%). Comparison of device manufacturers revealed that Biomet implants had significantly more reports of pain (χ2 = 10.21, p = 0.003), whereas Stryker implants had more infections (χ2 = 29.87, p < 0.001).
Conclusion
In summary, this in-depth analysis of adverse events provides a safety profile of TMJ implants. Understanding the complication types, management strategies, and outcomes according to device manufacturer may help set patient expectations and improve patient care.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA, dlakshmipathy@gmail.com.
- Leonard Davis Institute of Health Economics, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Zitieren
APA
Fritz, C., Wei, K., Ng, J., Lakshmipathy, D., & Rajasekaran, K. (2025). Adverse Events Associated with Surgically Implanted Temporomandibular Joint Devices. ORL. https://doi.org/10.1159/000543243
Vancouver
Fritz C, Wei K, Ng J, Lakshmipathy D, Rajasekaran K. Adverse Events Associated with Surgically Implanted Temporomandibular Joint Devices. ORL. 2025. doi:10.1159/000543243
BibTeX
@article{Fritz2025,
author = {Fritz, Christian and Wei, Kimberly and Ng, Jinggang and Lakshmipathy, Deepak and Rajasekaran, Karthik},
title = {Adverse Events Associated with Surgically Implanted Temporomandibular Joint Devices},
journal = {ORL},
year = {2025},
doi = {10.1159/000543243}
}
EUVIMED