EUVIMEDEUVIMED entdecken
Vergleichsstudie

Accuracy of Near-Infrared Imaging in Detection of Proximal Caries Lesions in Deciduous Molars: An in vitro Study

Suzana Oliveira, Regina Siegl, Kelly Moreira, Ana Flávia Calvo, José Carlos Pettorossi Imparato, Thais Gimenez, Suzana Oliveira

Caries Research · 2024

DOI: 10.1159/000543110 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Caries Research, 2024. Verfasst von Suzana Oliveira und 6 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Program in Pediatric Dentistry, Faculdade São Leopoldo Mandic, Campinas, Brazil. Hauptthemen laut MEDLINE: Dental Caries, Tooth, Deciduous, Molar. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The aim of this in vitro study was to evaluate the accuracy of near-infrared imaging (NIRI) generated by the iTero Element 5D scanner for detecting proximal caries lesions in deciduous molars, compared with visual inspection (VI), bitewing (BW) radiography, and histological examination (reference standard).

Methods

Sound deciduous molars and those with caries lesions (ICDAS 0 to 5) on the proximal surface were included, while teeth with marginal crest breakdown, restoration on the mentioned surfaces, or extensive dentin resorption were excluded. A total of 182 deciduous molars, divided into 91 pairs of first and second molars, were evaluated by two blinded examiners. Two distinct thresholds were considered for the assessment of caries detection methods: enamel lesion (D1) and dentin lesion (D3). Specificity, sensitivity, accuracy, and area under the ROC curve (AUC) were calculated for each method in the statistical analysis.

Results

All evaluated methods demonstrated high specificity at D1, with 1.00 for VI and 0.95 for NIRI and BW, and at D3, 0.99 for BW and 0.98 for NIRI and VI, without statistical differences. The sensitivity and accuracy of NIRI at D1 were 0.44 and 0.55, while those of VI were 0.46 and 0.58, and of BW were 0.60 and 0.68, respectively. And sensitivity and accuracy of NIRI at D3 were 0.14 and 0.69, while those of VI were 0.37 and 0.77, and of BW were 0.51 and 0.82, respectively. No difference in sensitivity and accuracy was observed between NIRI and VI at D1 (p = 0.589); however, NIRI presented the lowest accuracy at D3. At D1, no statistical difference was observed between the AUC of BW and VI (p = 0.1124), nor between NIRI and VI (p = 0.2523). However, at D3, statistical differences were observed between the AUCs of the three evaluated methods: VI versus NIRI (p = 0.0005), VI versus BW (p = 0.0281), and NIRI versus BW (p < 0.0001).

Conclusion

NIRI showed accuracy comparable to VI at the D1 threshold but was less effective than BW radiography at both D1 and D3 thresholds.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental CariesTooth, DeciduousMolarHumansSpectroscopy, Near-InfraredDentinSensitivity and SpecificityIn Vitro TechniquesDental EnamelRadiography, BitewingROC CurveReproducibility of ResultsPhysical Examination

Stichwörter der Autor:innen

Caries detectionDeciduous toothDental cariesEarly diagnosis

Autor:innen und Institutionen

  • Graduate Program in Pediatric Dentistry, Faculdade São Leopoldo Mandic, Campinas, Brazil.
  • Pediatric Dentistry, University of São Paulo, São Paulo, Brazil.

Zitieren

APA

Oliveira, S., Siegl, R., Moreira, K., Calvo, A. F., Imparato, J. C. P., Gimenez, T., & Oliveira, S. (2024). Accuracy of Near-Infrared Imaging in Detection of Proximal Caries Lesions in Deciduous Molars: An in vitro Study. Caries Research. https://doi.org/10.1159/000543110

Vancouver

Oliveira S, Siegl R, Moreira K, Calvo AF, Imparato JCP, Gimenez T, et al. Accuracy of Near-Infrared Imaging in Detection of Proximal Caries Lesions in Deciduous Molars: An in vitro Study. Caries Research. 2024. doi:10.1159/000543110

BibTeX
@article{Oliveira2024,
  author = {Oliveira, Suzana and Siegl, Regina and Moreira, Kelly and Calvo, Ana Flávia and Imparato, José Carlos Pettorossi and Gimenez, Thais and Oliveira, Suzana},
  title = {Accuracy of Near-Infrared Imaging in Detection of Proximal Caries Lesions in Deciduous Molars: An in vitro Study},
  journal = {Caries Research},
  year = {2024},
  doi = {10.1159/000543110}
}
Kostenlos starten →