In vivo Study to Evaluate an Intelligent Algorithm for Time Efficient Detection of Malignant Melanoma Using Dermatofluoroscopy
Skin Pharmacology and Physiology · 2024
DOI: 10.1159/000542854 ↗Kurz gefasst
Fachartikel in der Zeitschrift Skin Pharmacology and Physiology, 2024. Verfasst von Karl Weihmann und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, Venereology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humbol…. Hauptthemen laut MEDLINE: Melanoma, Algorithms, Dermoscopy, Skin Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Dermatofluoroscopy is an optical noninvasive method of melanoma/nevus differentiation that has shown 89% sensitivity and 45% specificity in clinical trials, but long measurement duration hinders clinical use. An intelligent algorithm was developed to shorten the measurement time without compromising its diagnostic accuracy. It uses dermoscopic images of the skin lesions to be measured to select measurement points based on the assessment of color values.
Methods
27 patients with a total of 29 lesions suggestive of cutaneous melanoma were included in a clinical study and measured with both methods, conventional dermatofluoroscopy and the newly developed intelligent algorithm. The results were compared to the independent findings of two histopathologists to evaluate diagnostic accuracy and time saved.
Results
There was a median reduction of measurement points from 265 to 158 (40%). Meanwhile, the intelligent algorithm showed a higher diagnostic accuracy than conventional dermatofluoroscopy (area under the curve of 72% vs. 63%).
Conclusion
The intelligent algorithm did not perform inferior to the conventional method while saving 40% of time. However, measurement times remain long compared to other noninvasive methods of diagnosing malignant melanoma. Further studies are needed to evaluate clinical suitability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dermatology, Venereology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
- Magnosco GmbH, Berlin, Germany.
Zitieren
APA
Weihmann, K., Schleusener, J., Eigentler, T. K., Ghoreschi, F. C., Moritz, R. K. C., Szyc, L., Dronnik, E., & Meinke, M. C. (2024). In vivo Study to Evaluate an Intelligent Algorithm for Time Efficient Detection of Malignant Melanoma Using Dermatofluoroscopy. Skin Pharmacology and Physiology. https://doi.org/10.1159/000542854
Vancouver
Weihmann K, Schleusener J, Eigentler TK, Ghoreschi FC, Moritz RKC, Szyc L, et al. In vivo Study to Evaluate an Intelligent Algorithm for Time Efficient Detection of Malignant Melanoma Using Dermatofluoroscopy. Skin Pharmacology and Physiology. 2024. doi:10.1159/000542854
BibTeX
@article{Weihmann2024,
author = {Weihmann, Karl and Schleusener, Johannes and Eigentler, Thomas K and Ghoreschi, Franziska C and Moritz, Rose K C and Szyc, Lukasz and Dronnik, Eduard and Meinke, Martina C},
title = {In vivo Study to Evaluate an Intelligent Algorithm for Time Efficient Detection of Malignant Melanoma Using Dermatofluoroscopy},
journal = {Skin Pharmacology and Physiology},
year = {2024},
doi = {10.1159/000542854}
}