EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients

Phong Yue Khoo, Chenshen Lam, Seng Fai Tang, Shamira Perera, Teck Chee Cheng, Norshamsiah Md Din

Ophthalmic Research · 2024

DOI: 10.1159/000542081 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Ophthalmic Research, 2024. Verfasst von Phong Yue Khoo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Intraocular Pressure, Glaucoma, Open-Angle, Phacoemulsification. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study investigated the intraocular pressure (IOP) fluctuation as assessed by the water drinking test (WDT) in open-angle glaucoma (OAG) patients after combined cataract surgery with iStent implantation.

Methods

This was a prospective non-randomized comparative study. Eyes with OAG and cataracts that were planned for either combined phacoemulsification and iStent implantation (iStent+CS) or phacoemulsification alone (CS) were recruited. The iStent inject (Model G2-M-IS) or iStent injectW (Model G2-W) trabecular micro-bypass stent (Glaukos Corporation, San Clemente, CA, USA) was implanted in the iStent+CS group. WDT was performed before and 3 months after surgery. WDT-IOP parameters including peak IOP, IOP fluctuation, and area under the curve (AUC) were compared between the two groups.

Results

There were 20 eyes in the iStent+CS group and 16 eyes in the CS group. Both groups had similar pre-operative baseline IOP (15.6 ± 3.7 mm Hg vs. 15.8 ± 1.8 mm Hg in the iStent+CS and CS group, respectively, p = 0.883). The iStent+CS group experienced greater numerical reduction in peak IOP (2.6 ± 1.9 mm Hg vs. 1.9 ± 2.4 mm Hg; p = 0.355), IOP fluctuation (1.7 ± 2.2 mm Hg vs. 0.8 ± 2.5 mm Hg; p = 0.289), and AUC (54.8 ± 103.6 mm Hg × minute vs. 25.3 ± 79.0 mm Hg × minute; p = 0.355) than the CS group. There was more reduction in the number of anti-glaucoma medications in the iStent+CS group (1.4 ± 1.2) than the CS group (0.3 ± 0.9; p = 0.005).

Conclusion

Both combined phacoemulsification with iStent inject implantation and phacoemulsification alone reduced peak IOP, IOP fluctuation, and AUC, and none of these parameters showed statistically significant difference. Greater reduction in anti-glaucoma medications was seen in the combined group.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intraocular PressureGlaucoma, Open-AnglePhacoemulsificationHumansProspective StudiesMaleFemaleAgedTonometry, OcularGlaucoma Drainage ImplantsMiddle AgedStentsDrinkingFollow-Up StudiesVisual Acuity

Stichwörter der Autor:innen

Intraocular pressure fluctuationOpen-angle glaucomaiStent

Autor:innen und Institutionen

  • Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Kuala Lumpur, Malaysia.
  • Hospital Canselor Tuanku Muhriz, Kuala Lumpur, Malaysia.
  • Optimax Eye Specialist Centre, Kuala Lumpur, Malaysia.
  • Singapore National Eye Centre, Singapore, Singapore.

Zitieren

APA

Khoo, P. Y., Lam, C., Tang, S. F., Perera, S., Cheng, T. C., & Md Din, N. (2024). Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients. Ophthalmic Research. https://doi.org/10.1159/000542081

Vancouver

Khoo PY, Lam C, Tang SF, Perera S, Cheng TC, Md Din N. Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients. Ophthalmic Research. 2024. doi:10.1159/000542081

BibTeX
@article{Khoo2024,
  author = {Khoo, Phong Yue and Lam, Chenshen and Tang, Seng Fai and Perera, Shamira and Cheng, Teck Chee and Md Din, Norshamsiah},
  title = {Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients},
  journal = {Ophthalmic Research},
  year = {2024},
  doi = {10.1159/000542081}
}
Kostenlos starten →