EUVIMEDEUVIMED entdecken
VergleichsstudieQuerschnittstudie

Correlation Between CT Renal Angiography of Live Kidney Donors and Intraoperative Findings: A Cross-sectional Study

Mzhda Sahib Jaafar, Naser Abdullah Mohammed, Shakhawan Hama Amin Said, Rawa Bapir, Dilan S Hiwa, Berun A Abdalla, Fahmi H Kakamad

Urologia Internationalis · 2024

DOI: 10.1159/000541816 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Urologia Internationalis, 2024. Verfasst von Mzhda Sahib Jaafar und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Medicine, University of Sulaimani, Sulaymaniyah, Iraq. Hauptthemen laut MEDLINE: Living Donors, Computed Tomography Angiography, Renal Artery, Kidney Transplantation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

A comprehensive understanding of the renal vascular anatomy variations is paramount to a successful kidney transplant. This reduces vascular injury risks and minimizes ischemia duration, optimizing surgical outcomes. The current study aims to assess the accuracy of renal computed tomography angiography (CTA) findings of live renal donors by comparing them with intraoperative findings.

Methods

This prospective cross-sectional study was conducted between October 2018 and February 2020. It included all healthy donors with two kidneys of normal size, shape, and position who were deemed suitable for nephrectomy. The CTA examinations were performed with the same protocol, which combined the vascular-excretory phase. A specialized radiologist confirmed anatomical findings. The CTA results were compared with intraoperative findings, which were documented by the transplantation team.

Results

The study included 220 patients. The preoperative CTA was highly sensitive and accurate, reaching 99.5% and 98.6%, respectively, for single vessels and 100% sensitivity and accuracy for triple vessels, pelvicalyceal system, and ureter duplication. The sensitivity of CTA for double vessels (vein and artery) was 90% and 92.6%, respectively, while accuracy was 98.6% for both.

Conclusion

CTA can be used to assess renal arteries and veins for potential renal donors with high accuracy. Although the CTA's minor, statistically non-significant discordance with the surgical findings regarding double arteries and veins, no artery or vein was missed on the CTA. Therefore, the sensitivity of CTA can reach 100%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Living DonorsComputed Tomography AngiographyRenal ArteryKidney TransplantationKidneyRenal VeinsHumansCross-Sectional StudiesMaleFemaleProspective StudiesAdultMiddle AgedNephrectomyIntraoperative Period

Stichwörter der Autor:innen

Computed tomography angiographyKidney transplantNephrectomyRenal transplant

Autor:innen und Institutionen

  • College of Medicine, University of Sulaimani, Sulaymaniyah, Iraq.
  • Smart Health Tower, Madam Mitterrand Street, Sulaymaniyah, Iraq.
  • Department of Urology, Sulaymaniyah Teaching Hospital, Sulaymaniyah, Iraq.
  • Kscien Organization for Scientific Research, Hamdi Street, Azadi Mall, Sulaymaniyah, Iraq.

Zitieren

APA

Jaafar, M. S., Mohammed, N. A., Said, S. H. A., Bapir, R., Hiwa, D. S., Abdalla, B. A., & Kakamad, F. H. (2024). Correlation Between CT Renal Angiography of Live Kidney Donors and Intraoperative Findings: A Cross-sectional Study. Urologia Internationalis. https://doi.org/10.1159/000541816

Vancouver

Jaafar MS, Mohammed NA, Said SHA, Bapir R, Hiwa DS, Abdalla BA, et al. Correlation Between CT Renal Angiography of Live Kidney Donors and Intraoperative Findings: A Cross-sectional Study. Urologia Internationalis. 2024. doi:10.1159/000541816

BibTeX
@article{Jaafar2024,
  author = {Jaafar, Mzhda Sahib and Mohammed, Naser Abdullah and Said, Shakhawan Hama Amin and Bapir, Rawa and Hiwa, Dilan S and Abdalla, Berun A and Kakamad, Fahmi H},
  title = {Correlation Between CT Renal Angiography of Live Kidney Donors and Intraoperative Findings: A Cross-sectional Study},
  journal = {Urologia Internationalis},
  year = {2024},
  doi = {10.1159/000541816}
}
Kostenlos starten →