EUVIMEDEUVIMED entdecken
Vergleichsstudie

The Clinical Impact of Urinalysis Screened by Automated Microscopy Compared to Reference Manual Analysis

Priscila Aparecida Correa Freitas, Yasmini Dandara Silva da Silva, José Antonio Tesser Poloni, Francisco José Veríssimo Veronese, Luiz Felipe Santos Goncalves

American Journal of Nephrology · 2024

DOI: 10.1159/000541561 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift American Journal of Nephrology, 2024. Verfasst von Priscila Aparecida Correa Freitas und 4 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate Program in Medicine, Medical Sciences, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil. Hauptthemen laut MEDLINE: Urinalysis, Microscopy, Kidney Diseases. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Clinical laboratories have replaced conventional manual urine microscopy with automated urinalysis; however, concerns persist regarding its validity in detecting specific elements of urinary sediment crucial for evaluating kidney diseases. This study aimed to assess the accuracy of urinary sediment analysis performed by a large hospital laboratory compared to a standardized microscopic review, focusing on patients both with and without kidney disease.

Methods

Urine samples were randomly selected from routine laboratory specimens at a university hospital. Laboratory analysis was performed using LabUmat 2 and Urised 3 PRO equipment (Abbott Diagnostics). In the automated analysis for sediment examination, technicians have the option to reclassify urinary sediment elements as necessary and, if warranted, conduct manual microscopic evaluations to validate findings. The laboratory’s analysis was compared with a “reference” analysis, which was double-blinded and conducted by two experienced technicians using bright-field and phase-contrast microscopy.

Results

503 samples were selected, with 52.3% originating from nephrology outpatient clinic patients. Overall agreement between the laboratory results and the reference analysis was 42.1%. The sensitivity (SN) of the laboratory examination for detecting pathological casts, lipiduria, and renal tubular epithelial cells was low (98%). However, for hyaline casts (SN: 50.4%; SP: 80.9%) and dysmorphic red blood cells (SN: 62.3%; SP: 96.2%), accuracy was intermediate. Performance was better for hematuria (SN: 86.1%; SP: 82.3%; intraclass correlation coefficient [ICC]: 0.703; R: 0.828) and leukocyturia (SN: 84.9%; SP: 95.1%; ICC: 0.807; R: 0.861). In patients with kidney disease (N = 248) and in samples manually reviewed by the laboratory (N = 115), accuracy for each urinary element was comparable to the overall sample findings. However, when assessing the ability to identify elements suggestive of nephropathy, only samples manually reviewed by the laboratory showed statistically similar results to those obtained by the reference analysis (p = 0.503, McNemar’s test).

Conclusion

Employing automated urinalysis seems to be accurate for detecting hematuria and leukocyturia, as well as for screening patients without kidney diseases. However, clinical laboratories attending complex patients should employ personalized strategies to help decide when to perform manual review, thus avoiding misleading urinalysis results.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UrinalysisMicroscopyKidney DiseasesHumansMaleFemaleMiddle AgedAgedAdultSensitivity and SpecificityHematuria

Stichwörter der Autor:innen

AccuracyAutomationClinical laboratoryMicroscopyUrinalysis

Autor:innen und Institutionen

  • Postgraduate Program in Medicine, Medical Sciences, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil.
  • Department of Laboratory Diagnostic, Hospital de Clínicas de Porto Alegre, Porto Alegre, Brazil.
  • Department of Education - Controllab, Rio de Janeiro, Brazil.
  • Department of Nephrology, Hospital de Clínicas de Porto Alegre, Porto Alegre, Brazil.

Zitieren

APA

Freitas, P. A. C., da Silva, Y. D. S., Poloni, J. A. T., Veronese, F. J. V., & Goncalves, L. F. S. (2024). The Clinical Impact of Urinalysis Screened by Automated Microscopy Compared to Reference Manual Analysis. American Journal of Nephrology. https://doi.org/10.1159/000541561

Vancouver

Freitas PAC, da Silva YDS, Poloni JAT, Veronese FJV, Goncalves LFS. The Clinical Impact of Urinalysis Screened by Automated Microscopy Compared to Reference Manual Analysis. American Journal of Nephrology. 2024. doi:10.1159/000541561

BibTeX
@article{Freitas2024,
  author = {Freitas, Priscila Aparecida Correa and da Silva, Yasmini Dandara Silva and Poloni, José Antonio Tesser and Veronese, Francisco José Veríssimo and Goncalves, Luiz Felipe Santos},
  title = {The Clinical Impact of Urinalysis Screened by Automated Microscopy Compared to Reference Manual Analysis},
  journal = {American Journal of Nephrology},
  year = {2024},
  doi = {10.1159/000541561}
}
Kostenlos starten →