Speech Perception Outcomes with the Anatomy-Based Fitting Map among Experienced, Adult Cochlear Implant Users: A Longitudinal Study

Pelden Wangchuk, Cila Umat, Foong Yen Chong, Faizah Mohd Zaki, Asma Abdullah

Audiology and Neurotology · 2024

DOI: 10.1159/000540965 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Audiology and Neurotology, 2024. Verfasst von Pelden Wangchuk und 4 weiteren Autor:innen. Beteiligte Einrichtung: Center for Rehabilitation and Special Needs Studies, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Speech Perception, Cochlear Implants, Cochlear Implantation, Prosthesis Fitting. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Anatomy-based fitting (ABF), a relatively new technique for cochlear implant (CI) programming, attempts to lessen the impact of the electrode insertion location-related frequency-to-place mismatch (FPM). This study aimed to compare vowels and consonant perception in quiet and in noise among experienced adult CI users using the ABF and the regular, conventional-based fitting (CBF) map (pre-ABF) over 6 months.

Methods

Nine ears from eight experienced adult CI users were included in the experimental and longitudinal research. Using surgical planning software called Otoplan, postoperative computed computed tomography scans were used to determine the locations of intracochlear electrodes and their angle of insertion. The anatomy-based frequency bands were produced by Maestro 9.0 CI fitting software using the Otoplan data. Nonsense syllables with consonant-vowel-consonant (CVC) recognition scores in quiet and noise (+5 dB SNR) were compared at baseline, 3, and 6 months after ABF. The vowels involved were /a, i, u/, while the consonants were voiced /b, d, g/ and voiceless /p, t, k/ plosives. Speech pieces were presented at 30 dB SL in a sound-treated room through a loudspeaker positioned at 0° azimuth.

Results

On average, the ABF maps shifted center frequency ranging from 0.46 semitones (0.04 octave) at (E12) to 23.94 semitones (1.99 octave) at (E1) as compared to the CBF maps. The mean vowel and consonant identification scores in quiet and in noise were significantly higher in ABF than in CBF (p < 0.05) with a large effect size and the trend of improvement was seen with time. Voiced consonants had better scores than the voiceless consonants.

Conclusion

The results demonstrated improved perception of vowels and consonants, particularly for sounds containing voicing cues after using the ABF maps. The results also suggested that ABF could be more effective for voice detection in noise. Overall, the findings indicate that correcting place mismatch with an ABF map may improve speech perception, at least among experienced adult CI users.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Speech PerceptionCochlear ImplantsCochlear ImplantationProsthesis FittingHumansMaleLongitudinal StudiesFemaleMiddle AgedAdultAgedTomography, X-Ray Computed

Stichwörter der Autor:innen

Anatomy-based fittingCochlear implantCochlear implant programmingFrequency-to-place mismatchVowel and consonant perception

Autor:innen und Institutionen

  • Center for Rehabilitation and Special Needs Studies, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia.
  • Audiology Unit, Department of Otorhinolaryngology, JDWNR Hospital, MoH, Thimphu, Bhutan.
  • Department of Radiology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia.
  • Department of Otorhinolaryngology-Head & Neck Surgery, Faculty of Medicine, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia.

Zitieren

APA

Wangchuk, P., Umat, C., Chong, F. Y., Zaki, F. M., & Abdullah, A. (2024). Speech Perception Outcomes with the Anatomy-Based Fitting Map among Experienced, Adult Cochlear Implant Users: A Longitudinal Study. Audiology and Neurotology. https://doi.org/10.1159/000540965

Vancouver

Wangchuk P, Umat C, Chong FY, Zaki FM, Abdullah A. Speech Perception Outcomes with the Anatomy-Based Fitting Map among Experienced, Adult Cochlear Implant Users: A Longitudinal Study. Audiology and Neurotology. 2024. doi:10.1159/000540965

BibTeX
@article{Wangchuk2024,
  author = {Wangchuk, Pelden and Umat, Cila and Chong, Foong Yen and Zaki, Faizah Mohd and Abdullah, Asma},
  title = {Speech Perception Outcomes with the Anatomy-Based Fitting Map among Experienced, Adult Cochlear Implant Users: A Longitudinal Study},
  journal = {Audiology and Neurotology},
  year = {2024},
  doi = {10.1159/000540965}
}
Kostenlos starten →