EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Intraoperative Compound Action Potentials as a Predictor of Postoperative Cortical Auditory Evoked Potentials in Cochlear Implant Users

Alexander Stutley, Caris Bogdanov, Marcus Windsor Rao Voola, Peter Friedland, Dayse Távora-Vieira

Audiology and Neurotology · 2024

DOI: 10.1159/000540576 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Audiology and Neurotology, 2024. Verfasst von Alexander Stutley und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Audiology, Fiona Stanley Fremantle Hospital Group, Perth, Washington, Australia. Hauptthemen laut MEDLINE: Evoked Potentials, Auditory, Cochlear Implantation, Cochlear Implants, Action Potentials. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Electrically evoked cortical auditory evoked potentials (ECAEPs) are central brain responses to auditory stimuli that correlate with postoperative cochlear implant (CI) hearing outcomes. They differ from electrically evoked compound action potentials (ECAPs) which are peripheral responses that can be elicited intraoperatively and may also predict CI hearing outcomes. It is not known to what degree ECAP and ECAEP responses are associated with each other. Such a correlation, if present, may allow for an earlier and more accurate prediction of postoperative hearing outcomes.

Methods

This retrospective study involved 42 adult CI users. Threshold levels and amplitude growth function slopes of intraoperative ECAPs were compared to the latencies and peak-to-peak amplitudes of postoperative ECAEP responses at three different cochlear electrode array sites (apical, medial, and basal).

Results

A weak positive relationship was found between intraoperative ECAP thresholds and ECAEP N1-P2 peak-to-peak amplitude (r = 0.301, p = 0.005). Time between ECAP and ECAEP measurements was weakly correlated with P1-N1 peak-to-peak amplitude (r = 0.321, p = 0.002) and ECAEP N1-P2 peak-to-peak amplitude (r = 0.340, p = 0.001). ECAP amplitude growth function slopes varied by electrode location (χ2 = 26.701, df = 2, p = 0. 000002).

Conclusion

These results suggest that intraoperative ECAP responses do not robustly predict postoperative ECAEP responses, providing caution against the use of ECAPs as a predictive tool for CI hearing outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Evoked Potentials, AuditoryCochlear ImplantationCochlear ImplantsAction PotentialsIntraoperative Neurophysiological MonitoringAuditory CortexHumansFemaleMaleRetrospective StudiesMiddle AgedAgedAdultPostoperative Period

Stichwörter der Autor:innen

Auditory evoked potentialCochlear implantCompound action potentialCortical auditory evoked potentialHearing outcome

Autor:innen und Institutionen

  • Department of Audiology, Fiona Stanley Fremantle Hospital Group, Perth, Washington, Australia.
  • Division of Surgery, Medical School, The University of Western Australia, Perth, Washington, Australia.
  • School of Occupational Therapy, Social Work and Speech Pathology, Faculty of Health Sciences, Curtin University, Perth, Washington, Australia.

Zitieren

APA

Stutley, A., Bogdanov, C., Voola, M. W. R., Friedland, P., & Távora-Vieira, D. (2024). Intraoperative Compound Action Potentials as a Predictor of Postoperative Cortical Auditory Evoked Potentials in Cochlear Implant Users. Audiology and Neurotology. https://doi.org/10.1159/000540576

Vancouver

Stutley A, Bogdanov C, Voola MWR, Friedland P, Távora-Vieira D. Intraoperative Compound Action Potentials as a Predictor of Postoperative Cortical Auditory Evoked Potentials in Cochlear Implant Users. Audiology and Neurotology. 2024. doi:10.1159/000540576

BibTeX
@article{Stutley2024,
  author = {Stutley, Alexander and Bogdanov, Caris and Voola, Marcus Windsor Rao and Friedland, Peter and Távora-Vieira, Dayse},
  title = {Intraoperative Compound Action Potentials as a Predictor of Postoperative Cortical Auditory Evoked Potentials in Cochlear Implant Users},
  journal = {Audiology and Neurotology},
  year = {2024},
  doi = {10.1159/000540576}
}
Kostenlos starten →