Fachartikel in der Zeitschrift Digital Biomarkers, online erschienen am 20.07.2024. Verfasst von Katherine Longardner und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosciences, University of California San Diego, San Diego, CA, USA. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NCATS NIH HHS.
Abstract (Originalsprache)
Introduction
Essential tremor is a common movement disorder. Numerous validated clinical rating scales exist to quantify essential tremor severity by employing rater-dependent visual observation but have limitations, including the need for trained human raters and the lack of precision and sensitivity compared to technology-based objective measures. Other continuous objective methods to quantify tremor amplitude have been developed, but frequently provide unitless measures (e.g., tremor power), limiting real-world interpretability. We propose a novel algorithm to measure kinetic tremor amplitude using digital spiral drawings, applying the V3 framework (sensor verification, analytical validation, and clinical validation) to establish reliability and clinical utility.
Methods
Archimedes spiral drawings were recorded on a digitizing tablet from participants (n = 7) enrolled in a randomized placebo control double-blinded crossover pilot trial evaluating the efficacy of oral cannabinoids in reducing essential tremor. We developed an algorithm to calculate the mean and maximum tremor amplitude derived from the spiral tracings. We compared the digitally measured tremor amplitudes to manual measurement to evaluate sensor reliability, determined the test-retest reliability of the digital output across two short-interval repeated measures, and compared the digital measure to kinetic tremor severity graded using The Essential Tremor Rating Assessment Scale (TETRAS) score for spiral drawings.
Results
This algorithm for automated assessment of kinetic tremor amplitude from digital spiral tracings demonstrated a high correlation with manual spot measures of tremor amplitude, excellent test-retest reliability, and a high correlation with human ratings of the TETRAS score for spiral drawing severity when the tremor severity was rated “slight tremor” or worse.
Discussion
This digital measure provides a simple and clinically relevant evaluation of kinetic tremor amplitude that shows promise as a potential future endpoint for use in clinical trials of essential tremor.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosciences, University of California San Diego, San Diego, CA, USA.
- Department of Psychiatry, University of California San Diego, San Diego, CA, USA.
- Ceretype Neuromedicine Inc, Cambridge, MA, USA.
- Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, USA.
Förderung
- NCATS NIH HHS
Zitieren
APA
Longardner, K., Shen, Q., Tang, B., Wright, B. A., Kundu, P., & Nahab, F. B. (2024). An Algorithm for Automated Measurement of Kinetic Tremor Magnitude Using Digital Spiral Drawings. Digital Biomarkers, 8(1), 140-148. https://doi.org/10.1159/000539529
Vancouver
Longardner K, Shen Q, Tang B, Wright BA, Kundu P, Nahab FB. An Algorithm for Automated Measurement of Kinetic Tremor Magnitude Using Digital Spiral Drawings. Digital Biomarkers. 2024;8(1):140-148. doi:10.1159/000539529
BibTeX
@article{Longardner2024,
author = {Longardner, Katherine and Shen, Qian and Tang, Bin and Wright, Brenton A and Kundu, Prantik and Nahab, Fatta B},
title = {An Algorithm for Automated Measurement of Kinetic Tremor Magnitude Using Digital Spiral Drawings},
journal = {Digital Biomarkers},
year = {2024},
volume = {8},
number = {1},
pages = {140--148},
doi = {10.1159/000539529}
}
EUVIMED