EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Choroidal Thickness in Healthy Eyes Measured by Widefield Optical Coherence Tomography

Blanca Eslava, Sofia Bryan, Mariluz Puertas, Jorge Ruiz-Medrano, José M Ruiz-Moreno

Ophthalmologica · 2024

DOI: 10.1159/000538129 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmologica, 2024. Verfasst von Blanca Eslava und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Puerta de Hierro-Majadahonda University Hospital, Madrid, Spain. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Choroid. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The choroid and its role in posterior segment pathology have become an increasing subject of study. The objective of the present study was to analyze choroidal thickness (CT) in healthy eyes by widefield (WF) optical coherence tomography (OCT) up to the periphery and to compare the reliability of manual versus automatic measurement.

Methods

Cross-sectional and noninterventional study conducted on 191 healthy eyes of 101 patients. All patients were scanned by using WF-OCT (Xephilio WF-OCT S1; Canon Corp, Tokyo, Japan). CT was measured in 2,000 μm intervals automatically using the built-in software and manually by two masked observers. All analyses were performed using the IBM-PSSS statistical software program (IBM-SPSS, v. 28.0.0.0, Chicago, IL, USA).

Results

CT was measured in 100% of the sample. The mean age of the study cohort was 39.05 ± 19.06 years old. Mean subfoveal CT measured automatically was 343.67 ± 84.18 μm and manually was 336.55 ± 75.57 μm. The thickest point was located 2,000 μm from the fovea in the superior sector in 62.83% of the subjects. According to age distribution, mean CT became significantly thinner from 40 years of age. When comparing automatic and manually measuring, the intraclass correlation coefficient was excellent (p < 0.01) in all quadrants. Moreover, manual measurement interobserver agreement was excellent in all quadrants (p < 0.01).

Conclusion

The automatic system is valid and serves as the basis of choroid measurement. In more than 50% of the healthy subjects, superior CT is thicker than subfoveolar CT and mean CT became significantly thinner from 40 years of age.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceChoroidHumansFemaleAdultCross-Sectional StudiesMaleReproducibility of ResultsMiddle AgedYoung AdultAgedAdolescentReference ValuesAged, 80 and overHealthy Volunteers

Stichwörter der Autor:innen

ChoroidWidefield optical coherence tomography

Autor:innen und Institutionen

  • Department of Ophthalmology, Puerta de Hierro-Majadahonda University Hospital, Madrid, Spain.
  • Department of Ophthalmology, Puerta de Hierro-Majadahonda University Hospital, Madrid, Spain, sbryan@ucm.es.
  • Department of Ophthalmology, Castilla de la Mancha University, Albacete, Spain.

Zitieren

APA

Eslava, B., Bryan, S., Puertas, M., Ruiz-Medrano, J., & Ruiz-Moreno, J. M. (2024). Choroidal Thickness in Healthy Eyes Measured by Widefield Optical Coherence Tomography. Ophthalmologica. https://doi.org/10.1159/000538129

Vancouver

Eslava B, Bryan S, Puertas M, Ruiz-Medrano J, Ruiz-Moreno JM. Choroidal Thickness in Healthy Eyes Measured by Widefield Optical Coherence Tomography. Ophthalmologica. 2024. doi:10.1159/000538129

BibTeX
@article{Eslava2024,
  author = {Eslava, Blanca and Bryan, Sofia and Puertas, Mariluz and Ruiz-Medrano, Jorge and Ruiz-Moreno, José M},
  title = {Choroidal Thickness in Healthy Eyes Measured by Widefield Optical Coherence Tomography},
  journal = {Ophthalmologica},
  year = {2024},
  doi = {10.1159/000538129}
}
Kostenlos starten →