Removal of a Metallic Stent after 9 Years of Placement That Caused Tracheal Stenosis: A Rare Case Report
Case Reports in Oncology · 02.02.2024 · 17 (1) · 186-190
DOI: 10.1159/000536213 ↗Kurz gefasst
Fallbericht in der Zeitschrift Case Reports in Oncology, online erschienen am 02.02.2024. Verfasst von Torahiko Nakashima und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Head and Neck Cancer Center, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
Metallic stents are widely used to prevent airway obstruction for tracheal stenosis caused by malignant diseases. Although their efficacy has been recognized, there is no established evidence surrounding their long-term safety. We report a case of airway stenosis caused by a metallic tracheal stent. Removal of the stent to secure the airway was difficult and extremely complicated. Case Presentation: A 50-year-old male suffering from dyspnea caused by malignant lymphoma (diffuse large B-cell lymphoma) of the thyroid gland was treated with a metallic tracheal stent. After remission of the lymphoma, stenosis of the stent lumen developed gradually, and the patient complained of dyspnea. Tracheostomy could not be performed due to the metallic stent. Since the patient was unable to intubate, the stent was removed under general anesthesia with partial percutaneous cardiopulmonary support 9 years after the stent placement.
Conclusion
Otolaryngologists should be aware of the possibility of severe stenosis following the long-term placement of a metallic tracheal stent.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology, Head and Neck Cancer Center, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan.
- Department of Thoracic Surgery, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan.
Zitieren
APA
Nakashima, T., Yamazaki, K., Uchi, R., & Uryu, H. (2024). Removal of a Metallic Stent after 9 Years of Placement That Caused Tracheal Stenosis: A Rare Case Report. Case Reports in Oncology, 17(1), 186-190. https://doi.org/10.1159/000536213
Vancouver
Nakashima T, Yamazaki K, Uchi R, Uryu H. Removal of a Metallic Stent after 9 Years of Placement That Caused Tracheal Stenosis: A Rare Case Report. Case Reports in Oncology. 2024;17(1):186-190. doi:10.1159/000536213
BibTeX
@article{Nakashima2024,
author = {Nakashima, Torahiko and Yamazaki, Koji and Uchi, Ryutaro and Uryu, Hideoki},
title = {Removal of a Metallic Stent after 9 Years of Placement That Caused Tracheal Stenosis: A Rare Case Report},
journal = {Case Reports in Oncology},
year = {2024},
volume = {17},
number = {1},
pages = {186--190},
doi = {10.1159/000536213}
}