EUVIMEDEUVIMED entdecken
Crossref

Performance of Biopsy Tools in Procurement of Lung Tissue in Robot-Assisted Peripheral Navigation: A Comparison

William D Meng, Mendy Lum, Elizabeth Yu, Ganesh Krishna

Respiration · 2023

DOI: 10.1159/000535234 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Respiration, 2023. Verfasst von William D Meng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary and Critical Care, Department of Medicine, University of California, San Francisco, California, USA. Hauptthemen laut MEDLINE: Robotics, Cryosurgery, Lung Neoplasms. Die Arbeit wurde bisher 5-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Robot-assisted navigation bronchoscopy (RANB) has been gaining traction as a new technology for minimally invasive biopsies of peripheral pulmonary lesions (PPLs). Cryobiopsy is an established method of procuring satisfactory lung tissues and can be safely paired with RANB. While some studies have evaluated the diagnostic accuracy and yield of this procedure, there is limited data on the utility of various biopsy tools, the sequence of use and differences in tissue characteristics based on the sampling techniques. Therefore, this study aims to examine the real-life performance of needle, forceps and cryoprobe when utilized in succession with RANB in the biopsy of PPLs, and to evaluate the specific types of tissue samples obtained from each instrument.

Methods

In a single-center retrospective study, 50 patients presenting 52 PPLs underwent biopsies sequentially using fine-needle aspiration (FNA), forceps, and cryoprobe. All procedures were performed via cone-beam CT-assisted RANB. Performance metrics, such as diagnostic yield, sensitivity, and specificity, were determined by classifying malignancy as true positives and explicit benign findings as true negatives. Tissue sizes and subtypes were based on pathology description and compared with Student’s t test and χ2, respectively.

Results

Cryobiopsy, when performed sequentially after FNA then forceps, was able to retrieve more alveolar tissue (p = 0.0098) among diagnosed lesions and showed higher diagnostic yield (p = 0.001) in PPL biopsy with RANB platform. Cryobiopsy was also able to obtain larger sample size (p = 0.0087). No difference was observed in the diagnosis of malignancy between forceps and cryobiopsy (p = 0.8877).

Conclusion

The integration of RANB and sequential biopsies, utilizing FNA, forceps, and cryoprobe, can efficiently diagnose PPLs and procure alveolar tissues. Further research based on histopathological subtypes is required to assess its prognostic significance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RoboticsCryosurgeryLung NeoplasmsHumansRetrospective StudiesLungBiopsyBronchoscopy

Stichwörter der Autor:innen

Alveolar tissueCryobiopsyForceps biopsyHistologyRobot-assisted navigation bronchoscopyTissue type comparison

Autor:innen und Institutionen

  • Division of Pulmonary and Critical Care, Department of Medicine, University of California, San Francisco, California, USA.
  • Division of Respiratory Medicine, Department of Medicine, El Camino Hospital, Mountain View, California, USA.
  • Division of Pulmonary and Critical Care, Department of Medicine, Palo Alto Medical Foundation, Palo Alto, California, USA.

Zitieren

APA

Meng, W. D., Lum, M., Yu, E., & Krishna, G. (2023). Performance of Biopsy Tools in Procurement of Lung Tissue in Robot-Assisted Peripheral Navigation: A Comparison. Respiration. https://doi.org/10.1159/000535234

Vancouver

Meng WD, Lum M, Yu E, Krishna G. Performance of Biopsy Tools in Procurement of Lung Tissue in Robot-Assisted Peripheral Navigation: A Comparison. Respiration. 2023. doi:10.1159/000535234

BibTeX
@article{Meng2023,
  author = {Meng, William D and Lum, Mendy and Yu, Elizabeth and Krishna, Ganesh},
  title = {Performance of Biopsy Tools in Procurement of Lung Tissue in Robot-Assisted Peripheral Navigation: A Comparison},
  journal = {Respiration},
  year = {2023},
  doi = {10.1159/000535234}
}
Kostenlos starten →