Comparison of a Multiplex Real-Time PCR Technique with Oxford Nanopore Technologies Next-Generation Sequencing for Identification of SARS-CoV-2 Variants of Concern
Intervirology · 2023
DOI: 10.1159/000534067 ↗Kurz gefasst
Fachartikel in der Zeitschrift Intervirology, 2023. Verfasst von Zahra Ahmadi und 8 weiteren Autor:innen. Beteiligte Einrichtung: COVID-19 National Reference Laboratory, Pasteur Institute of Iran, Tehran, Iran, zahraahmadii1995@gmail.com. Hauptthemen laut MEDLINE: COVID-19, Nanopores. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
The rapid emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants and their potential to endangering the global health has increased the demand for a fast-tracking method in comparison to the next-generation sequencing (NGS) as a gold standard assay, particularly in developing countries. This study was designed to evaluate the performance of a commercial multiplex real-time PCR technique (GA SARS-CoV-2 OneStep RT-PCR Kit, Iran) for identification of SARS-CoV-2 variants of concern (VOCs) compared to the Oxford Nanopore NGS assay.
Methods
A total of 238 SARS-CoV-2-positive respiratory samples from different waves of COVID-19 in Iran were randomly selected in this study. To determine the SARS-CoV-2 VOC, the samples were analyzed via the commercial triple target assay, GA SARS-CoV-2 OneStep RT-PCR Kit, and NGS as well.
Results
The results revealed good concordance between GA SARS-CoV-2 OneStep RT-PCR Kit and NGS for identification of SARS-CoV-2 VOCs. GA SARS-CoV-2 OneStep RT-PCR Kit identified Wuhan, Alpha, and Delta variants with 100% relative sensitivity and specificity. Regarding Omicron subvariants of BA.1, BA.2, and BA.4/5, the relative sensitivity of 100%, 100%, and 81.5% and the relative specificity of 95.3%, 93.5%, and 100% were observed.
Conclusion
Overall, GA SARS-CoV-2 OneStep RT-PCR Kit can be used as a rapid and cost-effective alternative to NGS for identification of SARS-CoV-2 VOCs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- COVID-19 National Reference Laboratory, Pasteur Institute of Iran, Tehran, Iran, zahraahmadii1995@gmail.com.
- COVID-19 National Reference Laboratory, Pasteur Institute of Iran, Tehran, Iran.
- Department of Influenza and Respiratory Viruses, Pasteur Institute of Iran, Tehran, Iran.
- Department of Epidemiology and Biostatistics, Pasteur Institute of Iran, Tehran, Iran.
- Department of Arboviruses and Viral Hemorrhagic Fevers (National Reference Laboratory), Pasteur Institute of Iran, Tehran, Iran.
- Research Center for Emerging and Reemerging Infectious Diseases, Pasteur Institute of Iran, Tehran, Iran.
Zitieren
APA
Ahmadi, Z., Maleki, A., Eybpoosh, S., Fereydouni, Z., Tavakoli, M., Kashanian, S., Farhan Asadi, L., Nemati, A. H., & Salehi-Vaziri, M. (2023). Comparison of a Multiplex Real-Time PCR Technique with Oxford Nanopore Technologies Next-Generation Sequencing for Identification of SARS-CoV-2 Variants of Concern. Intervirology. https://doi.org/10.1159/000534067
Vancouver
Ahmadi Z, Maleki A, Eybpoosh S, Fereydouni Z, Tavakoli M, Kashanian S, et al. Comparison of a Multiplex Real-Time PCR Technique with Oxford Nanopore Technologies Next-Generation Sequencing for Identification of SARS-CoV-2 Variants of Concern. Intervirology. 2023. doi:10.1159/000534067
BibTeX
@article{Ahmadi2023,
author = {Ahmadi, Zahra and Maleki, Ali and Eybpoosh, Sana and Fereydouni, Zahra and Tavakoli, Mahsa and Kashanian, Setareh and Farhan Asadi, Laya and Nemati, Amir Hesam and Salehi-Vaziri, Mostafa},
title = {Comparison of a Multiplex Real-Time PCR Technique with Oxford Nanopore Technologies Next-Generation Sequencing for Identification of SARS-CoV-2 Variants of Concern},
journal = {Intervirology},
year = {2023},
doi = {10.1159/000534067}
}
EUVIMED