EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Implementation of a Bleeding Management Algorithm in Liver Transplantation: A Pilot Study

Ignacio A Sarmiento, María F Guzmán, Javier Chapochnick, Jens Meier

Transfusion Medicine and Hemotherapy · 2024 · 51 (1) · 1-11

DOI: 10.1159/000530579 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Transfusion Medicine and Hemotherapy, online erschienen am 03.08.2023. Verfasst von Ignacio A Sarmiento und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Clínica Santa María, Santiago de Chile, Chile. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aims of the study were to compare the consumption of blood products before and after the implementation of a bleeding management algorithm in patients undergoing liver transplantation and to determine the feasibility of a multicentre, randomized study.

Background

Liver transplantation remains the only curative therapy for patients with end-stage liver disease, but it carries a high risk of surgical bleeding. Materials and Methods: Retrospective study of patients treated before (group 1) and after (group 2) implementation of a haemostatic algorithm guided by viscoelastic testing, including use of lyophilized coagulation factor concentrates (prothrombin complex and fibrinogen concentrates). Primary outcome was the number of units of blood products transfused in 24 h after surgery. Secondary outcomes included hospital stay, mortality, and cost.

Results

Data from 30 consecutive patients was analysed; 14 in group 1 and 16 in group 2. Baseline data were similar between groups. Median total blood product consumption 24 h after surgery was 33 U (IQR: 11–57) in group 1 and 1.5 (0–23.5) in group 2 (p = 0.028). Significantly fewer units of red blood cells, fresh frozen plasma, and cryoprecipitate were transfused in group 2 versus group 1. There was no significant difference in complications, hospital stay, or in-hospital mortality between groups. The cost of haemostatic therapy was non-significantly lower in group 2 versus group 1 (7,400 vs. 15,500 USD; p = 0.454).

Conclusion

The haemostatic management algorithm was associated with a significant reduction in blood product use during 24 h after liver transplantation. This study demonstrated the feasibility and provided a sample size calculation for a larger, randomized study.

Schlagwörter

Stichwörter der Autor:innen

BleedingHaemostasisLiver transplantViscoelastic testing

Autor:innen und Institutionen

  • Department of Anesthesiology, Clínica Santa María, Santiago de Chile, Chile.
  • Department of Anesthesiology, Universidad de los Andes, Santiago de Chile, Chile.
  • Department of Surgery, Clínica Santa María, Santiago de Chile, Chile.
  • Department for Anesthesiology and Critical Care, Kepler University Hospital, Johannes Kepler University, Linz, Austria.

Zitieren

APA

Sarmiento, I. A., Guzmán, M. F., Chapochnick, J., & Meier, J. (2024). Implementation of a Bleeding Management Algorithm in Liver Transplantation: A Pilot Study. Transfusion Medicine and Hemotherapy, 51(1), 1-11. https://doi.org/10.1159/000530579

Vancouver

Sarmiento IA, Guzmán MF, Chapochnick J, Meier J. Implementation of a Bleeding Management Algorithm in Liver Transplantation: A Pilot Study. Transfusion Medicine and Hemotherapy. 2024;51(1):1-11. doi:10.1159/000530579

BibTeX
@article{Sarmiento2024,
  author = {Sarmiento, Ignacio A and Guzmán, María F and Chapochnick, Javier and Meier, Jens},
  title = {Implementation of a Bleeding Management Algorithm in Liver Transplantation: A Pilot Study},
  journal = {Transfusion Medicine and Hemotherapy},
  year = {2024},
  volume = {51},
  number = {1},
  pages = {1--11},
  doi = {10.1159/000530579}
}
Kostenlos starten →