EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Visual Acuity and Visual Field Changes in Patients with End-Stage PACG with Tubular Visual Field after Cataract Surgery

Tian Hu, Lingjuan Xu, Xuhui Chen, Binbin Liu, Hong Zhang

Ophthalmic Research · 2023

DOI: 10.1159/000529778 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic Research, 2023. Verfasst von Tian Hu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China, hutianys@163.com. Hauptthemen laut MEDLINE: Glaucoma, Open-Angle, Glaucoma, Cataract, Glaucoma, Angle-Closure. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

To investigate the impact of cataract surgery on visual acuity and visual field (VF) in patients with end-stage glaucoma with tubular VF, and assess the risk of severe visual impairment.

Methods

Retrospective analysis of the case data of patients with end-stage glaucoma with tubular VF who underwent cataract surgery in our hospital in the past 7 years.

Results

A total of 59 patients with 63 eyes were enrolled, 62 eyes were primary angle-closure glaucoma (PACG) and 1 eye was primary open-angle glaucoma. The last follow-up time was an average of 9 months, and no cases of severe vision loss occurred. Best corrected visual acuity (BCVA) improved significantly after surgery (0.57 ± 0.46 vs. 0.45 ± 0.43 logarithm of the minimum angle of resolution, p < 0.01), and there was a significant drop in intraocular pressure (IOP; 22.85 ± 9.7 vs. 16.07 ± 3.38, p < 0.01), a reduced number of glaucoma medications (2 ± 1.32 vs. 0.5 ± 1, p < 0.01), statistical improvement in VF index (VFI) and mean defect (MD) (12.3% ± 7.65% vs. 16.1% ± 9.84%, p < 0.01; −29.09 ± 2.16 vs. −28.31 ± 3.01, p < 0.01) after surgery. The higher the preoperative VFI and MD were, the better the postoperative BCVA (r = −0.387, r = −0.347, respectively). The degree of postoperative VFI improvement was significantly correlated with preoperative MD (r = 0.372, p < 0.01). During the follow-up period, 5 eyes (8%) underwent anti-glaucoma surgery due to elevated IOP.

Conclusion

Cataract surgery can significantly improve visual acuity and VF in patients with end-stage PACG with tubular VF, and no patients have severe visual impairment. The less preoperative VF damage there is, the greater the postoperative visual acuity and VF improvement. Poor IOP control is the main cause of further damage to postoperative visual acuity and VF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glaucoma, Open-AngleGlaucomaCataractGlaucoma, Angle-ClosureHumansVisual FieldsRetrospective StudiesIntraocular PressureVisual AcuityVision Disorders

Stichwörter der Autor:innen

Cataract surgeryEnd-stage glaucomaTubular visual fieldVisual acuity

Autor:innen und Institutionen

  • Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China, hutianys@163.com.
  • Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.

Zitieren

APA

Hu, T., Xu, L., Chen, X., Liu, B., & Zhang, H. (2023). Visual Acuity and Visual Field Changes in Patients with End-Stage PACG with Tubular Visual Field after Cataract Surgery. Ophthalmic Research. https://doi.org/10.1159/000529778

Vancouver

Hu T, Xu L, Chen X, Liu B, Zhang H. Visual Acuity and Visual Field Changes in Patients with End-Stage PACG with Tubular Visual Field after Cataract Surgery. Ophthalmic Research. 2023. doi:10.1159/000529778

BibTeX
@article{Hu2023,
  author = {Hu, Tian and Xu, Lingjuan and Chen, Xuhui and Liu, Binbin and Zhang, Hong},
  title = {Visual Acuity and Visual Field Changes in Patients with End-Stage PACG with Tubular Visual Field after Cataract Surgery},
  journal = {Ophthalmic Research},
  year = {2023},
  doi = {10.1159/000529778}
}
Kostenlos starten →