Artificial Intelligence-Assisted Software Significantly Decreases All Workflow Metrics for Large Vessel Occlusion Transfer Patients, within a Large Spoke and Hub System
Cerebrovascular Diseases Extra · 14.02.2023 · 13 (1) · 41-46
DOI: 10.1159/000529077 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cerebrovascular Diseases Extra, online erschienen am 14.02.2023. Verfasst von Stavros Matsoukas und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA. Hauptthemen laut MEDLINE: Stroke, Brain Ischemia. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
Artificial intelligence (AI) software is increasingly applied in stroke diagnostics. Viz LVO (large vessel occlusion) is an AI-based software that is FDA-approved for LVO detection in CT angiography (CTA) scans. We sought to investigate differences in transfer times (from peripheral [spoke] to central [hub] hospitals) for LVO patients between spoke hospitals that utilize Viz LVO and those that do not.
Methods
In this retrospective cohort study, we used our institutional database to identify all suspected/confirmed LVO-transferred patients from spokes (peripheral hospitals) within and outside of our healthcare system, from January 2020 to December 2021. The “Viz-transfers” group includes all LVO transfers from spokes within our system where Viz LVO is readily available, while the “Non-Viz-transfers” group (control group) is comprised of all LVO transfers from spokes outside our system, without Viz LVO. Primary outcome included all available time metrics from peripheral CTA commencement.
Results
In total, 78 patients required a transfer. Despite comparable peripheral hospital door to peripheral hospital CTA times (20.5 [24.3] vs. 32 [45] min, p = 0.28) and transfer (spoke to hub) time (23 [18] vs. 26 [13.5], p = 0.763), all workflow metrics were statistically significantly shorter in the Viz-transfers group. Peripheral CTA to interventional neuroradiology team notification was 12 (16.8) versus 58 (59.5), p < 0.001, and peripheral CTA to peripheral departure was 91.5 (37) versus 122.5 (68.5), p < 0.001. Peripheral arrival to peripheral departure was 116.5 (75.5) versus 169 (126.8), p = 0.002, and peripheral arrival to central arrival was 145 (62.5) versus 207 (97.8), p < 0.001. In addition, peripheral CTA to angiosuite arrival was 121 (41) versus 207 (92.5), p < 0.001, peripheral CTA to arterial puncture was 146 (53) versus 234 (99.8), p < 0.001, and peripheral CTA to recanalization was 198 (25) versus 253.5 (86), p < 0.001.
Conclusion
Within our spoke and hub system, Viz LVO significantly decreased all workflow metrics for patients who were transferred from spokes with versus without Viz.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
- Department of Neurology, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Zitieren
APA
Matsoukas, S., Stein, L. K., & Fifi, J. (2023). Artificial Intelligence-Assisted Software Significantly Decreases All Workflow Metrics for Large Vessel Occlusion Transfer Patients, within a Large Spoke and Hub System. Cerebrovascular Diseases Extra, 13(1), 41-46. https://doi.org/10.1159/000529077
Vancouver
Matsoukas S, Stein LK, Fifi J. Artificial Intelligence-Assisted Software Significantly Decreases All Workflow Metrics for Large Vessel Occlusion Transfer Patients, within a Large Spoke and Hub System. Cerebrovascular Diseases Extra. 2023;13(1):41-46. doi:10.1159/000529077
BibTeX
@article{Matsoukas2023,
author = {Matsoukas, Stavros and Stein, Laura K and Fifi, Johanna},
title = {Artificial Intelligence-Assisted Software Significantly Decreases All Workflow Metrics for Large Vessel Occlusion Transfer Patients, within a Large Spoke and Hub System},
journal = {Cerebrovascular Diseases Extra},
year = {2023},
volume = {13},
number = {1},
pages = {41--46},