Quality Standards in Upper Gastrointestinal Endoscopy: Can Deep Sedation Influence It?
GE - Portuguese Journal of Gastroenterology · 2024 · 31 (2) · 101-109
DOI: 10.1159/000528977 ↗Kurz gefasst
Fachartikel in der Zeitschrift GE - Portuguese Journal of Gastroenterology, online erschienen am 17.03.2023. Verfasst von Catarina Correia und 7 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
According to the guideline published by ESGE/UEG, a high-quality esophagogastroduodenoscopy (EGD) implies the application of some criteria that enable better healthcare outcomes. Although intra-procedural performance measures are dependent on patient factors, there is no reference to sedation practices in the guideline mentioned above.
Objective
This study aimed to evaluate whether deep sedation influences EGD performance measures established by ESGE/UEG.
Methods
This was a cross-sectional study, with a prospective enrollment, that considered for inclusion consecutive patients referred for EGD. Two questionnaires were used to assess performance measures and patient satisfaction after EGD.
Results
Sedation had a statistically significant impact on most quality indicators, including complete examination (77.2% without sedation vs. 97.8% with sedation), inspection time (6.17 ± 3.45 vs. 8.39 ± 2.67 min), photodocumentation (78% vs. 97.8%), biopsies (39.3% vs. 60.7%), and patient satisfaction (5.42 ± 2.93 vs. 9.1 ± 1.19). The main reason for an incomplete procedure was patient intolerance (82.6%).
Discussion
Deep sedation of patients submitted to EGD proved to be a determinant in the applicability of the ESGE/UEG quality indicators. Patient intolerance was eliminated in the group with sedation, enhancing procedure completeness, adequate pathology identification, management, and consequently, the effectiveness of the exam.
Conclusion
Sedation administration should be considered in patients undergoing EGD since it ensures a high-quality procedure.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Gastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal.
- Faculty of Medicine, University of Coimbra, Coimbra, Portugal.
Zitieren
APA
Correia, C., Almeida, N., Andrade, R., Sant'Anna, M., Macedo, C., Perdigoto, D., Gregório, C., & Figueiredo, P. N. (2024). Quality Standards in Upper Gastrointestinal Endoscopy: Can Deep Sedation Influence It?. GE - Portuguese Journal of Gastroenterology, 31(2), 101-109. https://doi.org/10.1159/000528977
Vancouver
Correia C, Almeida N, Andrade R, Sant'Anna M, Macedo C, Perdigoto D, et al. Quality Standards in Upper Gastrointestinal Endoscopy: Can Deep Sedation Influence It?. GE - Portuguese Journal of Gastroenterology. 2024;31(2):101-109. doi:10.1159/000528977
BibTeX
@article{Correia2024,
author = {Correia, Catarina and Almeida, Nuno and Andrade, Raquel and Sant'Anna, Mariana and Macedo, Cláudia and Perdigoto, David and Gregório, Carlos and Figueiredo, Pedro Narra},
title = {Quality Standards in Upper Gastrointestinal Endoscopy: Can Deep Sedation Influence It?},
journal = {GE - Portuguese Journal of Gastroenterology},
year = {2024},
volume = {31},
number = {2},
pages = {101--109},
doi = {10.1159/000528977}
}