EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Quality Standards in Upper Gastrointestinal Endoscopy: Can Deep Sedation Influence It?

Catarina Correia, Nuno Almeida, Raquel Andrade, Mariana Sant'Anna, Cláudia Macedo, David Perdigoto, Carlos Gregório, Pedro Narra Figueiredo

GE - Portuguese Journal of Gastroenterology · 2024 · 31 (2) · 101-109

DOI: 10.1159/000528977 ↗

Kurz gefasst

Fachartikel in der Zeitschrift GE - Portuguese Journal of Gastroenterology, online erschienen am 17.03.2023. Verfasst von Catarina Correia und 7 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

According to the guideline published by ESGE/UEG, a high-quality esophagogastroduodenoscopy (EGD) implies the application of some criteria that enable better healthcare outcomes. Although intra-procedural performance measures are dependent on patient factors, there is no reference to sedation practices in the guideline mentioned above.

Objective

This study aimed to evaluate whether deep sedation influences EGD performance measures established by ESGE/UEG.

Methods

This was a cross-sectional study, with a prospective enrollment, that considered for inclusion consecutive patients referred for EGD. Two questionnaires were used to assess performance measures and patient satisfaction after EGD.

Results

Sedation had a statistically significant impact on most quality indicators, including complete examination (77.2% without sedation vs. 97.8% with sedation), inspection time (6.17 ± 3.45 vs. 8.39 ± 2.67 min), photodocumentation (78% vs. 97.8%), biopsies (39.3% vs. 60.7%), and patient satisfaction (5.42 ± 2.93 vs. 9.1 ± 1.19). The main reason for an incomplete procedure was patient intolerance (82.6%).

Discussion

Deep sedation of patients submitted to EGD proved to be a determinant in the applicability of the ESGE/UEG quality indicators. Patient intolerance was eliminated in the group with sedation, enhancing procedure completeness, adequate pathology identification, management, and consequently, the effectiveness of the exam.

Conclusion

Sedation administration should be considered in patients undergoing EGD since it ensures a high-quality procedure.

Schlagwörter

Stichwörter der Autor:innen

Quality standardsSedationUpper gastrointestinal endoscopy

Autor:innen und Institutionen

  • Gastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal.
  • Faculty of Medicine, University of Coimbra, Coimbra, Portugal.

Zitieren

APA

Correia, C., Almeida, N., Andrade, R., Sant'Anna, M., Macedo, C., Perdigoto, D., Gregório, C., & Figueiredo, P. N. (2024). Quality Standards in Upper Gastrointestinal Endoscopy: Can Deep Sedation Influence It?. GE - Portuguese Journal of Gastroenterology, 31(2), 101-109. https://doi.org/10.1159/000528977

Vancouver

Correia C, Almeida N, Andrade R, Sant'Anna M, Macedo C, Perdigoto D, et al. Quality Standards in Upper Gastrointestinal Endoscopy: Can Deep Sedation Influence It?. GE - Portuguese Journal of Gastroenterology. 2024;31(2):101-109. doi:10.1159/000528977

BibTeX
@article{Correia2024,
  author = {Correia, Catarina and Almeida, Nuno and Andrade, Raquel and Sant'Anna, Mariana and Macedo, Cláudia and Perdigoto, David and Gregório, Carlos and Figueiredo, Pedro Narra},
  title = {Quality Standards in Upper Gastrointestinal Endoscopy: Can Deep Sedation Influence It?},
  journal = {GE - Portuguese Journal of Gastroenterology},
  year = {2024},
  volume = {31},
  number = {2},
  pages = {101--109},
  doi = {10.1159/000528977}
}
Kostenlos starten →