Diagnostic Value of the Air-Bone Threshold Gap in Stapes Fixation
Audiology and Neurotology · 2023
DOI: 10.1159/000528826 ↗Kurz gefasst
Fachartikel in der Zeitschrift Audiology and Neurotology, 2023. Verfasst von Dongchul Cheon und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Yonsei University College of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Otosclerosis, Stapes Surgery. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Introduction
The Carhart notch is a well-known sign of stapes fixation. However, previous studies have reported that the Carhart notch is not specific to stapes fixation and is also present in other middle ear diseases. Therefore, this study investigated the diagnostic value of threshold gap between air conduction and bone conduction (ABG) for stapes fixation, instead of the bone conduction dip representing the Carhart notch.
Methods
A total of 199 ears that underwent exploratory tympanotomy were enrolled in this retrospective study. They were categorized into three groups according to surgical findings: stapes fixation (SF), other ossicle fixation (OF), and chain disconnection (CD). Preoperative pure-tone audiograms and impedance audiograms were compared between the groups.
Results
The incidence of the Carhart notch did not differ between the groups. The ABG at 2,000 Hz showed a good diagnostic performance for distinguishing between the SF and CD groups (area under the curve, AUC = 0.816, p < 0.001), but poor performance for distinguishing between the SF and OF groups (AUC = 0.662, p = 0.003). Bone conduction at 2,000 Hz showed a moderate performance for distinguishing between the SF and CD groups (AUC = 0.707, p < 0.001) and did not show statistically significant results for distinguishing between the SF and OF groups (AUC = 0.594, p = 0.080). The tympanic membrane compliance was significantly higher in the CD group than in the SF group (p = 0.001).
Conclusions
The Carhart notch was not a specific finding of SF. The sensitivity and specificity of ABG ≤15 dB at 2,000 Hz for distinguishing between SF and CD were 60.4% and 89.2%, respectively. To prepare for surgical interventions in patients with conductive hearing loss but a normal tympanic membrane, clinicians should comprehensively consider these results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology, Yonsei University College of Medicine, Seoul, Republic of Korea.
Zitieren
APA
Cheon, D., Kim, D., Kim, S. H., Choi, J. Y., & Bae, S. H. (2023). Diagnostic Value of the Air-Bone Threshold Gap in Stapes Fixation. Audiology and Neurotology. https://doi.org/10.1159/000528826
Vancouver
Cheon D, Kim D, Kim SH, Choi JY, Bae SH. Diagnostic Value of the Air-Bone Threshold Gap in Stapes Fixation. Audiology and Neurotology. 2023. doi:10.1159/000528826