Behavioural and Electrophysiological Evaluation of Loudness Growth in Clinically Normal Hearing Tinnitus Patients with and without Hyperacusis
Audiology and Neurotology · 2022 · 27 (6) · 469-477
DOI: 10.1159/000525692 ↗Kurz gefasst
Fachartikel in der Zeitschrift Audiology and Neurotology, online erschienen am 25.08.2022. Verfasst von Murat Erinc und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Audiology, Faculty of Medicine, Marmara University, Istanbul, Turkey. Hauptthemen laut MEDLINE: Hyperacusis, Tinnitus. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 50 Literaturangaben.
Abstract (Originalsprache)
Introduction
The common mechanism of tinnitus, hyperacusis, and loudness perception is hypothesized to be related to central gain. Although central gain increases with attempts to compensate hearing loss, reduced input can also be observed in those with clinically normal hearing. This study aimed to evaluate the loudness growth function of tinnitus patients with and without hyperacusis using behavioural and electrophysiological methods.
Methods
The study consists of three groups with a total of 60 clinically normal hearing subjects, including the control group (10 men and 10 women; mean age 39.8, SD 11.8 years), tinnitus group (10 men and 10 women; mean age 40.9, SD 12.2 years), and hyperacusis group (also have tinnitus) (7 men and 13 women; mean age 38.7, SD 14.6 years). Loudness discomfort levels (LDLs), categorical loudness scaling (CLS), and cortical auditory evoked potentials were used for the evaluation of loudness growth. N1-P2 component amplitudes and latencies were measured.
Results
LDL results of 500, 1,000, 2,000, 4,000, and 8,000 Hz showed a significant difference between the hyperacusis group and the other two groups (p < 0.001). In the loudness scale test performed with 500 Hz and 2,000 Hz narrow-band noise (NBN) stimulus, a significant difference was observed between the hyperacusis group and the other two groups in the “medium,” “loud,” and “very loud” categories (p < 0.001). In the cortical examination performed with 500 Hz and 2,000 Hz NBN stimulus at 40, 60, and 80 dB nHL intensities, no significant difference was observed between the groups in the N1, P2 latency, and N1-P2 peak-to-peak amplitude.
Conclusion
Although the hyperacusis group is significantly different between groups in behavioural tests, the same cannot be said for electrophysiological tests. In our attempt to differentiate tinnitus and hyperacusis with electrophysiological tests over the loudness growth function, N1 and P2 responses were not seen as suitable methods. However, it appears to be beneficial to use CLS in addition to LDLs in behavioural tests.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Audiology, Faculty of Medicine, Marmara University, Istanbul, Turkey.
- Department of Audiology, Faculty of Health Sciences, Istanbul Medeniyet University, Istanbul, Turkey.
Zitieren
APA
Erinc, M., & Derinsu, U. (2022). Behavioural and Electrophysiological Evaluation of Loudness Growth in Clinically Normal Hearing Tinnitus Patients with and without Hyperacusis. Audiology and Neurotology, 27(6), 469-477. https://doi.org/10.1159/000525692
Vancouver
Erinc M, Derinsu U. Behavioural and Electrophysiological Evaluation of Loudness Growth in Clinically Normal Hearing Tinnitus Patients with and without Hyperacusis. Audiology and Neurotology. 2022;27(6):469-477. doi:10.1159/000525692
BibTeX
@article{Erinc2022,
author = {Erinc, Murat and Derinsu, Ufuk},
title = {Behavioural and Electrophysiological Evaluation of Loudness Growth in Clinically Normal Hearing Tinnitus Patients with and without Hyperacusis},
journal = {Audiology and Neurotology},
year = {2022},
volume = {27},
number = {6},
pages = {469--477},
doi = {10.1159/000525692}
}
EUVIMED