Effects of Using Epidural Analgesia during Delivery on Maternal and Infant Outcomes
Gynecologic and Obstetric Investigation · 2022 · 87 (1) · 46-53
DOI: 10.1159/000522330 ↗Kurz gefasst
Fachartikel in der Zeitschrift Gynecologic and Obstetric Investigation, online erschienen am 16.03.2022. Verfasst von Fei Shuai und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Women and Children's Hospital, School of Medicine, Xiamen University, Xiamen, China. Hauptthemen laut MEDLINE: Analgesia, Epidural, Analgesia, Obstetrical, Labor, Obstetric. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Objectives
The aim of the study was to estimate the impact of epidural analgesia (EA) during delivery on maternal and infant outcomes.
Design
This was a prospective cohort study.
Participants
In total, 159 pregnant multiparas in Women and Children’s Hospital, School of Medicine, Xiamen University from November 2019 to May 2020 were enrolled. Patients were divided into the EA group (n = 80) and no analgesia group (n = 79) based on the choice of the parturients.
Methods
The duration of labor, levels of umbilical arterial blood gas (pH and partial pressure oxygen), visual analog score (VAS), and adverse events were evaluated to compare differences between the EA group and no analgesia group, respectively.
Results
The duration of labor was prolonged in the entire labor (p = 0.002), and the first stage (p = 0.001) in the EA group compared with the no analgesia group. The second stage of labor and third stage of labor, levels of umbilical arterial blood gas, and 1-min Apgar score in neonates were similar in EA and no analgesia groups (All p > 0.05). After adjusting age, prepregnancy body mass index, and past and present medical history, the VAS was low in the EA group compared with the no analgesia group when the uterine orifice was completely open (odds ratio [OR] = 0.001, 95% confidence interval [CI]: 0.001–0.002), 8 h postdelivery (OR = 0.508, 95% CI: 0.264–0.977), and 24 h postdelivery (OR = 0.321, 95% CI: 0.167–0.617). EA increased the proportion of adverse events occurring 5 min postdelivery (χ2 = 10.137, p = 0.001), while decreased the proportion of adverse events occurring 24 h postdelivery (χ2 = 4.750, p = 0.029).
Limitations
In terms of the effects of EA on neonates, we only measured the 1-min Apgar score of neonates.
Conclusions
EA might be a reliable pain relief method for pregnant women. The results of our study might give a reference for the use of EA during delivery in clinic.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Women and Children's Hospital, School of Medicine, Xiamen University, Xiamen, China.
Zitieren
APA
Shuai, F., Jia, J., & Lin, P. (2022). Effects of Using Epidural Analgesia during Delivery on Maternal and Infant Outcomes. Gynecologic and Obstetric Investigation, 87(1), 46-53. https://doi.org/10.1159/000522330
Vancouver
Shuai F, Jia J, Lin P. Effects of Using Epidural Analgesia during Delivery on Maternal and Infant Outcomes. Gynecologic and Obstetric Investigation. 2022;87(1):46-53. doi:10.1159/000522330
BibTeX
@article{Shuai2022,
author = {Shuai, Fei and Jia, Junxiang and Lin, Peng},
title = {Effects of Using Epidural Analgesia during Delivery on Maternal and Infant Outcomes},
journal = {Gynecologic and Obstetric Investigation},
year = {2022},
volume = {87},
number = {1},
pages = {46--53},
doi = {10.1159/000522330}
}
EUVIMED