The Continuing Need for Electron Microscopy in Examination of Medical Renal Biopsies: Examples in Practice
Glomerular Diseases · 16.06.2021 · 1 (3) · 145-159
DOI: 10.1159/000516831 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Glomerular Diseases, online erschienen am 16.06.2021. Verfasst von Michifumi Yamashita und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Laboratory Medicine, Cedars-Sinai Medical Center, Los Angeles, California, USA. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NCATS NIH HHS.
Abstract (Originalsprache)
Background: For the better part of the past 6 decades, transmission electron microscopy (EM), together with routine light microscopy and immunofluorescence and/or immunohistochemistry (IHC), has been an essential component of the diagnostic workup of medical renal biopsies, particularly native renal biopsies, with increasing frequency in renal allograft biopsies as well. Studies performed prior to the year 2000 have indeed shown that a substantial fraction of renal biopsies cannot be accurately diagnosed without EM. Still, EM remains costly and labor-intensive, and with increasing pressure to reduce healthcare costs, some centers are de-emphasizing diagnostic EM. This trend has been coupled with advances in IHC and other methods in renal biopsy diagnosis over the past 2–3 decades. Summary: Nonetheless, it has been our experience that the diagnostic value of EM in the comprehensive evaluation of renal biopsies remains similar to what it was 20–30 years ago. In this review, we provide several key examples from our practice where EM was essential in making the correct renal biopsy diagnosis, ranging from relatively common glomerular lesions to rare diseases. Key Messages: EM remains an important component of the diagnostic evaluation of medical renal biopsies. Failure to perform EM in certain cases will result in an incorrect diagnosis, with possible clinical consequences. We strongly recommend that tissue for EM be taken and stored in an appropriate fixative and ultrastructural studies be performed for all native renal biopsies, as well as appropriate renal allograft biopsies as recommended by the Banff consortium.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pathology and Laboratory Medicine, Cedars-Sinai Medical Center, Los Angeles, California, USA.
Förderung
- NCATS NIH HHS
Zitieren
APA
Yamashita, M., Lin, M. Y., Hou, J., Ren, K. Y. M., & Haas, M. (2021). The Continuing Need for Electron Microscopy in Examination of Medical Renal Biopsies: Examples in Practice. Glomerular Diseases, 1(3), 145-159. https://doi.org/10.1159/000516831
Vancouver
Yamashita M, Lin MY, Hou J, Ren KYM, Haas M. The Continuing Need for Electron Microscopy in Examination of Medical Renal Biopsies: Examples in Practice. Glomerular Diseases. 2021;1(3):145-159. doi:10.1159/000516831
BibTeX
@article{Yamashita2021,
author = {Yamashita, Michifumi and Lin, Mercury Y and Hou, Jean and Ren, Kevin Y M and Haas, Mark},
title = {The Continuing Need for Electron Microscopy in Examination of Medical Renal Biopsies: Examples in Practice},
journal = {Glomerular Diseases},
year = {2021},
volume = {1},
number = {3},
pages = {145--159},
doi = {10.1159/000516831}
}
EUVIMED