EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Magnification Effect of Foveal Avascular Zone Measurement Using Optical Coherence Tomography Angiography

Mika Suda, Yuji Yoshikawa, Gaku Terauchi, Soiti Matsumoto, Takuhei Shoji, Kei Shinoda, Atsushi Mizota, Yoshiharu Kobayashi

Biomedicine Hub · 12.06.2020 · 5 (2) · 1-8

DOI: 10.1159/000507501 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedicine Hub, online erschienen am 12.06.2020. Verfasst von Mika Suda und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthoptics, Teikyo University Faculty of Medical Technology, Tokyo, Japan. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study was to evaluate the foveal avascular zone (FAZ) of healthy subjects and examine the magnification effect.

Methods

A total of 33 healthy volunteers were enrolled and all subjects were eligible for analysis. Optical coherence tomography angiography (OCTA) examination scanned 3 × 3 mm of the macular area. The FAZ area was measured on the superficial OCTA en face image with and without correction by axial length. The relationship between changes in the FAZ area after correction with the axial length was examined.

Results

The mean age was 21.9 ± 0.6 years. The mean axial length was 24.87 ± 1.17 mm and mean spherical equivalent (SE) value was –3.64 ± 2.83 diopters (D). The FAZ area was 0.26 ± 0.10 mm2 before the axial length correction and 0.27 ± 0.10 mm2 after the correction. In the eyes that had an axial length longer than or equal to 26 mm or SE less than or equal to –6 D, the FAZ area after correction was significantly larger than that before correction (p < 0.01). The change of FAZ area after correction with axial length was significantly correlated with the axial length (R2 = 0.88, p < 0.01) or SE value (R2 = 0.55, p < 0.01).

Conclusion

FAZ areas were comparable to previous reports. In high myopic cases, the magnification effect needs to be considered when evaluating the FAZ area.

Schlagwörter

Stichwörter der Autor:innen

Axial lengthFoveal avascular zoneMagnification effectMyopiaOptical coherence tomography angiography

Autor:innen und Institutionen

  • Department of Orthoptics, Teikyo University Faculty of Medical Technology, Tokyo, Japan.
  • Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
  • Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan.

Zitieren

APA

Suda, M., Yoshikawa, Y., Terauchi, G., Matsumoto, S., Shoji, T., Shinoda, K., Mizota, A., & Kobayashi, Y. (2020). Magnification Effect of Foveal Avascular Zone Measurement Using Optical Coherence Tomography Angiography. Biomedicine Hub, 5(2), 1-8. https://doi.org/10.1159/000507501

Vancouver

Suda M, Yoshikawa Y, Terauchi G, Matsumoto S, Shoji T, Shinoda K, et al. Magnification Effect of Foveal Avascular Zone Measurement Using Optical Coherence Tomography Angiography. Biomedicine Hub. 2020;5(2):1-8. doi:10.1159/000507501

BibTeX
@article{Suda2020,
  author = {Suda, Mika and Yoshikawa, Yuji and Terauchi, Gaku and Matsumoto, Soiti and Shoji, Takuhei and Shinoda, Kei and Mizota, Atsushi and Kobayashi, Yoshiharu},
  title = {Magnification Effect of Foveal Avascular Zone Measurement Using Optical Coherence Tomography Angiography},
  journal = {Biomedicine Hub},
  year = {2020},
  volume = {5},
  number = {2},
  pages = {1--8},
  doi = {10.1159/000507501}
}
Kostenlos starten →