Utilization of a Novel, Multi-Durometer Intracranial Distal Access Catheter: Nuances and Experience in 110 Consecutive Cases of Aneurysm Flow Diversion
Interventional Neurology · 2017 · 6 (1-2) · 90-104
DOI: 10.1159/000456086 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interventional Neurology, online erschienen am 03.02.2017. Verfasst von Geoffrey P Colby und 8 weiteren Autor:innen. Beteiligte Einrichtung: Johns Hopkins University School of Medicine, Baltimore, MD, CA, USA. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Coaxial catheter support systems provide a safe and stable foundation in endovascular treatment of intracranial aneurysms. Increasingly, robust distal intracranial support is sought during complex neurointerventions. The AXS Catalyst 5 distal access catheter (Cat5) is a new intracranial catheter designed for improved trackability and stability. We report the first experience using Cat5 for aneurysm treatment by flow diversion.
Methods
A single-center aneurysm database was reviewed for cases of aneurysm treatment with the Pipeline embolization device (PED) that utilized Cat5. Data were collected for patient demographics, aneurysm characteristics, procedural details, catheter positions, vessel tortuosity, and catheter related complications.
Results
One hundred and ten cases of aneurysm flow diversion were successfully performed using Cat5. Patient age ranged from 21 to 86 years (mean 57 ± 12.5 years) with 84% women. Aneurysm size ranged from 2 to 28 mm (mean 5.7 ± 5.0 mm), with 97% in the anterior circulation. Twenty-four aneurysms (22%) were located beyond the ICA termination. Significant cervical carotid tortuosity was present in 26% of cases, and moderate to severe cavernous tortuosity (cavernous grade ≥2) in 45% of cases. Cat5 was tracked to the intended distal position in all cases with 100% technical success of PED implantation. No iatrogenic catheter-related vessel injury occurred, and major neurological morbidity occurred in 1 patient (1%). Summary: The Cat5 is a novel, multi-durometer cranial distal access catheter designed for use in tri-axial systems. We have demonstrated the utility of Cat5 in 110 successful cases of flow diversion with a wide range of complexity. This catheter is a new tool in the neurointerventionalist's armamentarium to achieve robust and atraumatic distal access.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Johns Hopkins University School of Medicine, Baltimore, MD, CA, USA.
- UC Irvine Health, School of Medicine, Orange, CA, USA.
Zitieren
APA
Colby, G. P., Lin, L. M., Xu, R., Beaty, N., Bender, M. T., Jiang, B., Huang, J., Tamargo, R. J., & Coon, A. L. (2017). Utilization of a Novel, Multi-Durometer Intracranial Distal Access Catheter: Nuances and Experience in 110 Consecutive Cases of Aneurysm Flow Diversion. Interventional Neurology, 6(1-2), 90-104. https://doi.org/10.1159/000456086
Vancouver
Colby GP, Lin LM, Xu R, Beaty N, Bender MT, Jiang B, et al. Utilization of a Novel, Multi-Durometer Intracranial Distal Access Catheter: Nuances and Experience in 110 Consecutive Cases of Aneurysm Flow Diversion. Interventional Neurology. 2017;6(1-2):90-104. doi:10.1159/000456086
BibTeX
@article{Colby2017,
author = {Colby, Geoffrey P and Lin, Li-Mei and Xu, Risheng and Beaty, Narlin and Bender, Matthew T and Jiang, Bowen and Huang, Judy and Tamargo, Rafael J and Coon, Alexander L},
title = {Utilization of a Novel, Multi-Durometer Intracranial Distal Access Catheter: Nuances and Experience in 110 Consecutive Cases of Aneurysm Flow Diversion},
journal = {Interventional Neurology},
year = {2017},
volume = {6},
number = {1-2},
pages = {90--104},
doi = {10.1159/000456086}
}
EUVIMED