EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Buffer Additives and Packaging Differentially Influence the Stability of Dyes Commonly Used in Chromovitrectomy

Begoña Parrado Aliod, Wilfried Kugler, Tim Häring

Biomedicine Hub · 2016

DOI: 10.1159/000452241 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedicine Hub, 2016. Verfasst von Begoña Parrado Aliod und 2 weiteren Autor:innen. Beteiligte Einrichtung: Fluoron GmbH, Ulm, Germany. Die Arbeit nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study was performed to investigate the chemical stability of different dyes used in chromovitrectomy and the influence of various product parameters on it.

Methods

Buffered dye solutions were prepared containing 1.5 g/L acid violet 17, 0.25 g/L brilliant blue G, 1.3 g/L bromophenol blue, and 1.5 g/L trypan blue, combined with deuterium oxide, polyethylene glycol 3350, and D-mannitol as additives. For accelerated storage testing, samples were incubated for 400 h at 80°C corresponding to 2 years according to the Van ‘t Hoff equation. After different incubation times samples were taken for UV/Vis spectroscopy, pH measurement, and osmometry.

Results

Depending on dye, additive, and packaging, different solutions exhibit differences in chemical stability and hence shelf life. Packaging in syringes instead of vials increases dye stability. Additives may negatively influence important parameters, e.g. polyethylene glycol 3350 increases osmolality beyond the physiological range. Notably, acid violet 17 is chemically unstable except in D-mannitol-containing buffer, packed in syringes. However, simultaneously, D-mannitol leads to a pH shift below 7.0.

Conclusion

In summary, dye solutions filled in syringes should be preferred to vials to slow down oxidative degradation. Especially acid violet 17 solutions should be used with caution because the addition of D-mannitol may contribute to pH values beyond the physiological range.

Schlagwörter

Stichwörter der Autor:innen

ChromovitrectomyD-MannitolDeuterium oxideInternal limiting membrane stainingMacular holesPolyethylene glycol 3350

Autor:innen und Institutionen

  • Fluoron GmbH, Ulm, Germany.

Zitieren

APA

Parrado Aliod, B., Kugler, W., & Häring, T. (2016). Buffer Additives and Packaging Differentially Influence the Stability of Dyes Commonly Used in Chromovitrectomy. Biomedicine Hub. https://doi.org/10.1159/000452241

Vancouver

Parrado Aliod B, Kugler W, Häring T. Buffer Additives and Packaging Differentially Influence the Stability of Dyes Commonly Used in Chromovitrectomy. Biomedicine Hub. 2016. doi:10.1159/000452241

BibTeX
@article{ParradoAliod2016,
  author = {Parrado Aliod, Begoña and Kugler, Wilfried and Häring, Tim},
  title = {Buffer Additives and Packaging Differentially Influence the Stability of Dyes Commonly Used in Chromovitrectomy},
  journal = {Biomedicine Hub},
  year = {2016},
  doi = {10.1159/000452241}
}
Kostenlos starten →