Clinical and Microbiological Evaluation of an Extended-Wear Hearing Instrument
Audiology and Neurotology Extra · 2014
DOI: 10.1159/000363213 ↗Kurz gefasst
Fachartikel in der Zeitschrift Audiology and Neurotology Extra, 2014. Verfasst von Jae Hoon Sim und 7 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
This study aimed to examine the integrity of the ear canal skin and its microbiological changes caused by an extended-wear hearing device. An extended-wear hearing device, Lyric2 (Phonak AG, Switzerland), which is the second generation of the Lyric device, was fitted to 52 ears of 27 subjects. A refit of the device was done for a selection of ears (n = 15) for which the initial fitting was interrupted (28 ears). A matching control group consisted of 10 ears of 10 subjects with no history of using any form of hearing aid for 3 months. The ear canal skin of ears fitted with the hearing device was inspected using an otoendoscope, and signs of problematic pathological conditions were graded. Microbiological examinations were performed at three different stages following fitting. Wearing the device was interrupted in 28 (53.8%) out of the 52 ears for the initial fitting, and 17 of the 28 interrupted cases (60.7%) were due to issues of the ear canal skin. In 3 of 15 ears (25%) following a refitting, wearing the device was interrupted yet again, and 1 of these 3 interruptions was caused by ear canal skin pathologies. Growth of bacteria was not enhanced or prompted by wearing the Lyric2, and Gram-negative bacteria could not be cultured while the device was in place. Based on aspects of ear canal skin pathology, continuous and nonproblematic uses of the Lyric2 device are presumed to be obtained if the fitting is done carefully. Wearing of the Lyric2 device can be considered safe from a microbiological perspective and does not promote growth of Gram-negative bacteria.
Zitieren
APA
Sim, J. H., Xie, Y., Karamuk, E., Kameke, A. V., Holder, J. T., Zbinden, R., Röösli, C., & Huber, A. M. (2014). Clinical and Microbiological Evaluation of an Extended-Wear Hearing Instrument. Audiology and Neurotology Extra. https://doi.org/10.1159/000363213
Vancouver
Sim JH, Xie Y, Karamuk E, Kameke AV, Holder JT, Zbinden R, et al. Clinical and Microbiological Evaluation of an Extended-Wear Hearing Instrument. Audiology and Neurotology Extra. 2014. doi:10.1159/000363213
BibTeX
@article{Sim2014,
author = {Sim, Jae Hoon and Xie, Youzhou and Karamuk, Erdal and Kameke, Alexander von and Holder, Jens Ten and Zbinden, Reinhard and Röösli, Christof and Huber, Alexander M.},
title = {Clinical and Microbiological Evaluation of an Extended-Wear Hearing Instrument},
journal = {Audiology and Neurotology Extra},
year = {2014},
doi = {10.1159/000363213}
}