Removal Characteristics and Total Dialysate Content of Glutamine and Other Amino Acids in Critically Ill Patients with Acute Kidney Injury Undergoing Extended Dialysis
Nephron Clinical Practice · 22.02.2014 · 126 (1) · 62-66
DOI: 10.1159/000358434 ↗Kurz gefasst
Klinische Studie in der Zeitschrift Nephron Clinical Practice, online erschienen am 22.02.2014. Verfasst von Julius J Schmidt und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nephrology and Hypertension, Department of Internal Medicine, Hannover Medical School, Hannover, Germany. Hauptthemen laut MEDLINE: Renal Dialysis. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
Background
Acute kidney injury in critically ill patients is associated with the activation of protein catabolism and a negative nitrogen balance. Renal replacement therapy (RRT) aggravates this problem by eliminating a substantial amount of amino acids. However, there is scarce data on the removal characteristics of modern dialysis membranes in extended dialysis.
Methods
This is a prospective study in 10 extended dialysis sessions using a 1.8-m2 polysulfone membrane (EMiC2 dialyzer or AV 1000S; FMC, Germany). Blood samples for 19 amino acids were drawn before, during, and after 10 h of extended dialysis (blood/dialysate flow 150 ml/min). In addition, samples for the calculation of dialyzer clearance and samples from the total spent dialysate were measured using a Biochrom 30 amino acid analyzer.
Results
Despite no significant difference in pre- and postdialysis plasma amino acid levels, we found an impressive amount of amino acids in collected spent dialysate, i.e. 10.5 g/10 h of treatment. The dialyzer clearance ranged from 67.6 ml/min for phenylalanine to 140.0 ml/min for valine. The total eliminated masses of the measured amino acids had equal values for both membranes. There was a significant difference between the dialyzer clearance of the investigated membranes for glutamine (AV 1000S: 83.3 ml/min vs. EMiC2: 92.0 ml/min, p = 0.02) and serine (88.8 ml/min vs. 91.8 ml/min, p = 0.005).
Discussion
Our data indicate that the modern forms of RRT eliminate amino acids to an extent that has not been met by our nutritional support standards. Especially the removal of glutamine, important for immune function and cell regeneration, might have detrimental effects on the recovery of critically ill patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Division of Nephrology and Hypertension, Department of Internal Medicine, Hannover Medical School, Hannover, Germany.
Zitieren
APA
Schmidt, J. J., Hafer, C., Spielmann, J., Hadem, J., Schönenberger, E., Schmidt, B. M., & Kielstein, J. T. (2014). Removal Characteristics and Total Dialysate Content of Glutamine and Other Amino Acids in Critically Ill Patients with Acute Kidney Injury Undergoing Extended Dialysis. Nephron Clinical Practice, 126(1), 62-66. https://doi.org/10.1159/000358434
Vancouver
Schmidt JJ, Hafer C, Spielmann J, Hadem J, Schönenberger E, Schmidt BM, et al. Removal Characteristics and Total Dialysate Content of Glutamine and Other Amino Acids in Critically Ill Patients with Acute Kidney Injury Undergoing Extended Dialysis. Nephron Clinical Practice. 2014;126(1):62-66. doi:10.1159/000358434
BibTeX
@article{Schmidt2014,
author = {Schmidt, Julius J and Hafer, Carsten and Spielmann, Julia and Hadem, Johannes and Schönenberger, Eva and Schmidt, Bernhard M W and Kielstein, Jan T},
title = {Removal Characteristics and Total Dialysate Content of Glutamine and Other Amino Acids in Critically Ill Patients with Acute Kidney Injury Undergoing Extended Dialysis},
journal = {Nephron Clinical Practice},
year = {2014},
volume = {126},
number = {1},
pages = {62--66},
doi = {10.1159/000358434}
}
EUVIMED