GJB2 Variants and Auditory Outcomes among Filipino Cochlear Implantees
Audiology and Neurotology Extra · 2013
DOI: 10.1159/000346271 ↗Kurz gefasst
Fachartikel in der Zeitschrift Audiology and Neurotology Extra, 2013. Verfasst von Charlotte M. Chiong und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Objectives
To determine the prevalence of gap junction beta-2 (GJB2) or connexin 26 variants in Filipino cochlear implantees, and to describe radiologic findings, audiologic results and auditory performance after cochlear implantation (CI).
Methods
Thirty cochlear implantees with unknown etiology of congenital severe-to-profound hearing loss and 30 controls provided venous blood samples for study. Radiologic evidence of temporal bone abnormalities, residual hearing status and post-CI auditory performance are described. Statistical analysis was performed for hearing thresholds before and after CI and for Parent Evaluation of Auditory/Oral Performance in Children (PEACH) scores based on the presence of cochleovestibular anomalies, age at CI and time since CI. Genomic DNA was extracted from venous blood, PCR-amplified and sequenced for GJB2 variants.
Results
One patient was compound heterozygous (c.[35delG ];[235delC]) for GJB2 variants. The variants p.Gly4Asp, p.Val27Ile and p.Val37Ile were identified in both patients and controls, including 2 implantees who were homozygous for p.Val27Ile and p.Val37Ile. No significant association was found between post-CI improvement in threshold or PEACH scores and the following variables: age at CI, duration of hearing aid use prior to CI, presence of cochleovestibular anomalies and completeness of electrode insertion. Although no significant change in audiometric thresholds due to time since CI was detected, PEACH scores were significantly improved with longer implant use at all conditions (quiet, noise and overall; p < 0.05).
Conclusions
The prevalence of causal GJB2 variants in Filipino cochlear implantees is low (3.3%). Within this population, the allele frequency of the p.Val37Ile variant in patients and controls is >10%, which supports a nonpathogenic role for this variant. The low prevalence of GJB2 variants precluded any association testing with CI outcome, although our results suggest better auditory outcome with longer CI use. Future genetic studies within the Filipino population should be able to control for population admixture.
Zitieren
APA
Chiong, C. M., Paz, E. M. C. L., Reyes-Quintos, M. R. T., Tobias, C. A. M., Hernandez, K., & Santos-Cortez, R. L. P. (2013). GJB2 Variants and Auditory Outcomes among Filipino Cochlear Implantees. Audiology and Neurotology Extra. https://doi.org/10.1159/000346271
Vancouver
Chiong CM, Paz EMCL, Reyes-Quintos MRT, Tobias CAM, Hernandez K, Santos-Cortez RLP. GJB2 Variants and Auditory Outcomes among Filipino Cochlear Implantees. Audiology and Neurotology Extra. 2013. doi:10.1159/000346271
BibTeX
@article{Chiong2013,
author = {Chiong, Charlotte M. and Paz, Eva Maria Cutiongco-de la and Reyes-Quintos, Maria Rina T. and Tobias, Celina Ann M. and Hernandez, Karen and Santos-Cortez, Regie Lyn P.},
title = {GJB2 Variants and Auditory Outcomes among Filipino Cochlear Implantees},
journal = {Audiology and Neurotology Extra},
year = {2013},
doi = {10.1159/000346271}
}
EUVIMED