EUVIMEDEUVIMED entdecken
Vergleichsstudie

Serum Cystatin C Is a More Sensitive and More Accurate Marker of Glomerular Filtration Rate than Enzymatic Measurements of Creatinine in Renal Transplantation

Anders Christensson, Jana Ekberg, Anders Grubb, Henrik Ekberg, Veronica Lindström, Hans Lilja

Nephron Physiology · 2003

DOI: 10.1159/000071287 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Nephron Physiology, 2003. Verfasst von Anders Christensson und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nephrology and Transplantation, Malmö University Hospital, Malmö, Sweden. Anders.Christensson@medforsk.mas.lu.se. Die Arbeit wurde bisher 63-mal zitiert (Crossref) und nennt 3 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Aims: Serum creatinine has several drawbacks as marker of glomerular filtration rate (GFR), and therefore serum cystatin C has been proposed as a more optimal GFR marker. Previous reports have suggested benefits of serum cystatin C measurements in patients with renal transplants. The purpose of the present study was to evaluate the diagnostic accuracy of cystatin C measurements compared with enzymatic creatinine measurements as serum markers of GFR (established from plasma clearance of iohexol) in a large cohort of stable renal transplant recipients and in the early postoperative phase.

Methods

Renal transplant patients (n = 125) with stable graft function were evaluated from reciprocals of serum creatinine and cystatin C compared with iohexol clearance. Fourteen patients were examined immediately after the onset of renal function. Cystatin C was measured by a particle-enhanced turbidimetric method and creatinine by an enzymatic method.

Results

In stable renal transplant recipients, serum cystatin C showed a significantly (p = 0.033) closer correlation (r = 0.89 or 79% co-variance) with iohexol clearance than did serum creatinine (r = 0.81 or 66% co-variance). Using the χ2 test and a cut-off at 60 ml/min/1.73 m2, serum cystatin C levels demonstrated significantly higher sensitivity for early GFR impairment (p = 0.0045) compared with serum creatinine measurements. On the first day after transplantation, serum cystatin C fell more rapidly than serum creatinine.

Conclusion

Serum cystatin C levels correlate significantly closer to accurate measurements of GFR and are significantly more sensitive to detect early GFR impairment than enzymatic measurements of creatinine in serum.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AdultAgedAmidohydrolasesBiomarkersCohort StudiesCreatinineCystatin CCystatinsGlomerular Filtration RateHumansIohexolKidney Failure, ChronicKidney GlomerulusKidney TransplantationMaleMiddle AgedSensitivity and Specificity

Substanzen

BiomarkersCST3 protein, humanCystatin CCystatinsIohexolCreatinineAmidohydrolasescreatininase

Autor:innen und Institutionen

  • Department of Nephrology and Transplantation, Malmö University Hospital, Malmö, Sweden. Anders.Christensson@medforsk.mas.lu.se

Zitieren

APA

Christensson, A., Ekberg, J., Grubb, A., Ekberg, H., Lindström, V., & Lilja, H. (2003). Serum Cystatin C Is a More Sensitive and More Accurate Marker of Glomerular Filtration Rate than Enzymatic Measurements of Creatinine in Renal Transplantation. Nephron Physiology. https://doi.org/10.1159/000071287

Vancouver

Christensson A, Ekberg J, Grubb A, Ekberg H, Lindström V, Lilja H. Serum Cystatin C Is a More Sensitive and More Accurate Marker of Glomerular Filtration Rate than Enzymatic Measurements of Creatinine in Renal Transplantation. Nephron Physiology. 2003. doi:10.1159/000071287

BibTeX
@article{Christensson2003,
  author = {Christensson, Anders and Ekberg, Jana and Grubb, Anders and Ekberg, Henrik and Lindström, Veronica and Lilja, Hans},
  title = {Serum Cystatin C Is a More Sensitive and More Accurate Marker of Glomerular Filtration Rate than Enzymatic Measurements of Creatinine in Renal Transplantation},
  journal = {Nephron Physiology},
  year = {2003},
  doi = {10.1159/000071287}
}
Kostenlos starten →