EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of Air Pollutants on Lightning Activities in Kathmandu, Nepal

P B Adhikari iD, J S Dhami, K N Poudyal, N P Chapagain

The Scientific World Journal · 2026-01 · 2026 (1)

DOI: 10.1155/tswj/8125403 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Scientific World Journal, online erschienen am 19.03.2026. Verfasst von P B Adhikari und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Tri-Chandra Multiple Campus, Tribhuvan University (TU), Kathmandu, Nepal, ioe.edu.np. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Coordination and Development Council (RCDC).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An electric field mill (EFM‐100) short‐range sensor has been installed on the rooftop of the six story building of Kathmandu BernHardt College, Tribhuvan University (TU), Bafal, Kathmandu for continuous monitoring of lightning events within a 38 km in aerial distance. It constantly monitors lightning activities and activates graphical display alerts on a connected computer. The EFM‐100 monitor software displays a real time graph of the atmospheric electrical field, as well as the distance of lightning strikes within the specified range. Lightning strikes were recorded over a 3‐month period, spanning 57 days, primarily during the both premonsoon and monsoon seasons, from May 19 to August 18, 2024. In addition, the effect of lightning events on atmospheric pollutants such as PM 1 , PM 2.5 , PM 10 , relative humidity, temperature, and particle density of ozone per cubic centimeter were analyzed. These atmospheric parameters were obtained from the Central Department of Environment Science, TU, Nepal. The results clearly show that the atmospheric pollutants PM 1 , PM 2.5 , and PM 10 , found to be higher during the lightning events. PM 2.5 concentrations increased by an average of approximately 18%, PM 10 by about 12%, and ozone by about 22% compared with prelightning background levels. Similarly, the atmospheric temperature increased by 1.5°C–2.0°C during the strong lightning events followed by a gradual decrease thereafter. These findings provide clear evidence of the magnitude of pollutants and thermal changes associated with lightning. It was also observed that relative humidity is inversely proportional to temperature, as it rises due to lightning phenomena. Furthermore, lightning activity was found to significantly increase with rising concentrations of ozone particles in the atmosphere.

Schlagwörter

Stichwörter der Autor:innen

atmospheric pollutantslightningrelative humiditytemperature

Autor:innen und Institutionen

  • Department of Physics, Tri-Chandra Multiple Campus, Tribhuvan University (TU), Kathmandu, Nepal, ioe.edu.np.
  • Department of Applied Sciences and Chemical Engineering, IOE Pulchowk Campus, TU, Lalitpur, Nepal.
  • Department of Physics, Amrit Campus, TU, Kathmandu, Nepal.

ORCID-Profile: P B Adhikari

Förderung

  • Research Coordination and Development Council (RCDC)

Zitieren

APA

Adhikari, P. B., Dhami, J. S., Poudyal, K. N., & Chapagain, N. P. (2026). Impact of Air Pollutants on Lightning Activities in Kathmandu, Nepal. The Scientific World Journal, 2026(1). https://doi.org/10.1155/tswj/8125403

Vancouver

Adhikari PB, Dhami JS, Poudyal KN, Chapagain NP. Impact of Air Pollutants on Lightning Activities in Kathmandu, Nepal. The Scientific World Journal. 2026;2026(1). doi:10.1155/tswj/8125403

BibTeX
@article{Adhikari2026,
  author = {Adhikari, P B and Dhami, J S and Poudyal, K N and Chapagain, N P},
  title = {Impact of Air Pollutants on Lightning Activities in Kathmandu, Nepal},
  journal = {The Scientific World Journal},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/tswj/8125403}
}
Kostenlos starten →