EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Novel Transformer‐Based Anomaly Detection Model for the Reactor Coolant Pump in Nuclear Power Plants

Guangrong Zhou, Sheng Zheng, Senquan Yang, Shuang Yi

Science and Technology of Nuclear Installations · 2024-01 · 2024 (1)

DOI: 10.1155/stni/9455897 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science and Technology of Nuclear Installations, online erschienen am 30.11.2024. Verfasst von Guangrong Zhou und 3 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China National Nuclear Corporation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As a key equipment of the reactor coolant system, the reactor coolant pump’s operational state can have a direct impact on the coolant circulation. However, the harsh working environment can accelerate the process of equipment deterioration for the reactor coolant pump while the current alarm mechanism cannot detect the deterioration of equipment performance at the early stage. This issue may lead to anomalies developing into faults and causing unplanned shutdowns and reactor trips. In this paper, we proposed a transformer‐based anomaly detection model for reactor coolant pump condition monitoring. On the basis of retaining the time‐dependent capture ability of the original transformer network for sequence data, the proposed model has obtained a stronger learning ability of the spatial correlation between variables through the application of the attention mechanism. Historical operating data under normal conditions are used for the training process and the reconstruction errors of input signals are utilized to identify anomalies. The experimental results have indicated that the proposed model possesses stronger feature learning capabilities, evidenced by improved performance in signal reconstruction and anomaly detection, which can help to detect the abnormal status at an earlier stage.

Förderung

  • China National Nuclear Corporation

Zitieren

APA

Zhou, G., Zheng, S., Yang, S., & Yi, S. (2024). A Novel Transformer‐Based Anomaly Detection Model for the Reactor Coolant Pump in Nuclear Power Plants. Science and Technology of Nuclear Installations, 2024(1). https://doi.org/10.1155/stni/9455897

Vancouver

Zhou G, Zheng S, Yang S, Yi S. A Novel Transformer‐Based Anomaly Detection Model for the Reactor Coolant Pump in Nuclear Power Plants. Science and Technology of Nuclear Installations. 2024;2024(1). doi:10.1155/stni/9455897

BibTeX
@article{Zhou2024,
  author = {Zhou, Guangrong and Zheng, Sheng and Yang, Senquan and Yi, Shuang},
  title = {A Novel Transformer‐Based Anomaly Detection Model for the Reactor Coolant Pump in Nuclear Power Plants},
  journal = {Science and Technology of Nuclear Installations},
  year = {2024},
  volume = {2024},
  number = {1},
  doi = {10.1155/stni/9455897}
}
Kostenlos starten →