Effect of Displacement‐Dependent Stiffness Devices on Seismic Performance of Isolated Bridges
Structural Control and Health Monitoring · 2026-01 · 2026 (1)
DOI: 10.1155/stc/8695387 ↗Kurz gefasst
Fachartikel in der Zeitschrift Structural Control and Health Monitoring, online erschienen am 19.08.2026. Verfasst von Christos D. Varsamis und 2 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alexander S. Onassis Public Benefit Foundation.
Abstract (Originalsprache)
Seismic isolation systems have been employed in bridges to increase their lateral flexibility and thereby improve their performance by reflecting seismic energy away from the structure. In recent years, stiffness devices that could passively generate both positive and negative tangential stiffness that varies with displacement were introduced within bridge isolation systems in an attempt to further improve seismic performance by reducing their lateral stiffness to near‐zero values and thus increasing the fundamental natural period to near‐infinity. Previous investigations on such displacement‐dependent stiffness devices have focused on their effect on the seismic response of existing bridges, where design parameters that characterize the behavior of stiffness devices often had values from preliminary designs or, at best, values obtained from sensitivity studies. A potentially different level of performance could be realized in the design of a new bridge if the isolation system components (bearings, dampers, and stiffness devices) were designed simultaneously through optimization. This study concentrates on an evaluation of the effectiveness of displacement‐dependent stiffness devices in improving the response of a bridge with a well‐designed (optimized) seismic isolation system. A design framework is developed that optimizes configurations of the isolation system for multiple performance objectives. It is found that for a bridge with an isolation system comprised only of lead‐rubber bearings, the inclusion of stiffness devices can, in certain cases, result in improved seismic performance. In contrast, for a bridge with a high‐performance isolation system comprised of lead‐rubber bearings and dampers, the inclusion of stiffness devices provides negligible improvement in seismic performance.
Förderung
- Alexander S. Onassis Public Benefit Foundation
Zitieren
APA
Varsamis, C. D., Symans, M. D., & Warn, G. P. (2026). Effect of Displacement‐Dependent Stiffness Devices on Seismic Performance of Isolated Bridges. Structural Control and Health Monitoring, 2026(1). https://doi.org/10.1155/stc/8695387
Vancouver
Varsamis CD, Symans MD, Warn GP. Effect of Displacement‐Dependent Stiffness Devices on Seismic Performance of Isolated Bridges. Structural Control and Health Monitoring. 2026;2026(1). doi:10.1155/stc/8695387
BibTeX
@article{Varsamis2026,
author = {Varsamis, Christos D. and Symans, Michael D. and Warn, Gordon P.},
title = {Effect of Displacement‐Dependent Stiffness Devices on Seismic Performance of Isolated Bridges},
journal = {Structural Control and Health Monitoring},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/stc/8695387}
}
EUVIMED