Lumbar Facet Joint Radiofrequency Ablation With a 3‐Tined Cannula: A Technical Report and Observational Study
Pain Research and Management · 2024
DOI: 10.1155/prm/8871568 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Pain Research and Management, 2024. Verfasst von Andrea Künzle und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Biomedical Sciences, Università della Svizzera Italiana, Lugano, Switzerland. Hauptthemen laut MEDLINE: Zygapophyseal Joint, Low Back Pain, Radiofrequency Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Lumbar facet joints are the source of pain in 15%–41% of individuals experiencing low back pain (LBP). Conventional lumbar facet radiofrequency ablation (RFA) has Level II evidence for improving pain and function. The best proven technique, the parallel technique, is technically challenging, time‐consuming, and often uncomfortable for the patient. A novel RFA technique using a 3‐tined cannula offers a potentially less complex and shorter procedure.
Objectives
To describe the novel lumbar facet joint RFA technique with the 3‐tined cannula and to evaluate its efficacy in treating chronic lumbar facet joint pain.
Methods
Eligible adult patients with chronic lumbar facet joint pain, confirmed by positive medial branch blocks (MBBs), refractory to conservative treatment, received the novel RFA treatment with the 3‐tined cannula. The change in pain intensity at 2 months follow‐up compared to baseline, percentage of patients reporting a ≥ 30% and ≥ 50% reduction of pain intensity, patient global impression of change (PGIC), need for pain medication, walking ability, sleep quality, and patient satisfaction were evaluated.
Results
A total of 44 patients were included. Patients experienced a clinically meaningful and significant pain relief at follow‐up and 41% of the patients reported ≥ 50% reduction of pain. Forty‐eight percent experienced at least a score of “much improved” on the PGIC. No severe side effects or complications were observed.
Conclusions
Our observational study suggests that lumbar facet joint RFA using the novel technique achieves significant pain relief. The larger lesions decrease the likelihood of missing the target nerve while obviating the need to conduct numerous lesions. Limiting is the single‐center set‐up with a relatively short‐term follow‐up duration. Randomized controlled clinical trials are warranted to confirm the efficacy of the novel RFA technique to treat lumbar facet joint pain.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Biomedical Sciences, Università della Svizzera Italiana, Lugano, Switzerland.
- Pain Management Center, Neurocenter of Southern Switzerland, EOC, Lugano, Switzerland.
- Department of Clinical Epidemiology and Medical Technology Assessment, Maastricht University Medical Center+, Maastricht, Netherlands.
ORCID-Profile: Andrea Künzle, Sander M J van Kuijk, Eva Koetsier
Zitieren
APA
Künzle, A., van Kuijk, S. M. J., & Koetsier, E. (2024). Lumbar Facet Joint Radiofrequency Ablation With a 3‐Tined Cannula: A Technical Report and Observational Study. Pain Research and Management. https://doi.org/10.1155/prm/8871568
Vancouver
Künzle A, van Kuijk SMJ, Koetsier E. Lumbar Facet Joint Radiofrequency Ablation With a 3‐Tined Cannula: A Technical Report and Observational Study. Pain Research and Management. 2024. doi:10.1155/prm/8871568
BibTeX
@article{Knzle2024,
author = {Künzle, Andrea and van Kuijk, Sander M J and Koetsier, Eva},
title = {Lumbar Facet Joint Radiofrequency Ablation With a 3‐Tined Cannula: A Technical Report and Observational Study},
journal = {Pain Research and Management},
year = {2024},
doi = {10.1155/prm/8871568}
}
EUVIMED