Device Type and Age Independently Predict Gram‐Negative Cerebrospinal Fluid Device–Related Infection: A Retrospective Comparative Study
Neurology Research International · 2026-01 · 2026 (1)
DOI: 10.1155/nri/5940088 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neurology Research International, online erschienen am 22.11.2026. Verfasst von Suleiman S. Daoud und 5 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Cerebrospinal fluid (CSF) device–related infection is a major complication of CSF diversion, yet the microbiological and inflammatory consequences of the device used are incompletely defined. We compared the clinical features, microbiological spectra, and CSF laboratory profiles of infections associated with ventriculoperitoneal (VP) shunts versus external ventricular drains (EVDs) and identified independent predictors of Gram‐negative infection.
Method
We performed a retrospective comparative analysis of 74 patients with culture‐confirmed CSF device‐related infection (42 VP, 32 EVD). Demographic, clinical, microbiological, CSF laboratory, and outcome variables were compared between device groups using the Mann–Whitney U test for continuous variables and the Fisher exact or χ 2 test for categorical variables. Standard multivariable and Firth penalized logistic regression models were fitted to identify independent predictors of Gram‐negative infection.
Results
Patients with EVD infection were older than those with VP infection (median 21.5 vs. 4.2 years; p = 0.029), and a smaller proportion were pediatric (47% vs. 69%). Underlying indications differed ( p = 0.004), with hemorrhagic and tumor‐related indications more common in the EVD group. Gram‐positive organisms predominated in the VP group (30/42, 71%) and Gram‐negative organisms in the EVD group (19/32, 59%) ( p = 0.006); coagulase‐negative staphylococci and Acinetobacter baumannii were the most frequent Gram‐positive and Gram‐negative isolates, respectively. In multivariable analysis, EVD (adjusted OR 3.44, 95% CI 1.20–9.88; p = 0.022) and adult age (adjusted OR 4.38, 95% CI 1.52–12.59; p = 0.006) were independently associated with Gram‐negative infection.
Conclusion
Device type and patient age strongly structure the microbiology and inflammatory profile of CSF device‐related infection.
Zitieren
APA
Daoud, S. S., Hulliel, A. F., Jarrar, S., Jaradat, A., Saleh, D., & Abdallah, A. (2026). Device Type and Age Independently Predict Gram‐Negative Cerebrospinal Fluid Device–Related Infection: A Retrospective Comparative Study. Neurology Research International, 2026(1). https://doi.org/10.1155/nri/5940088
Vancouver
Daoud SS, Hulliel AF, Jarrar S, Jaradat A, Saleh D, Abdallah A. Device Type and Age Independently Predict Gram‐Negative Cerebrospinal Fluid Device–Related Infection: A Retrospective Comparative Study. Neurology Research International. 2026;2026(1). doi:10.1155/nri/5940088
BibTeX
@article{Daoud2026,
author = {Daoud, Suleiman S. and Hulliel, Atef F. and Jarrar, Sultan and Jaradat, Amer and Saleh, Dana and Abdallah, Adam},
title = {Device Type and Age Independently Predict Gram‐Negative Cerebrospinal Fluid Device–Related Infection: A Retrospective Comparative Study},
journal = {Neurology Research International},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/nri/5940088}
}
EUVIMED