EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Triple‐Cavity Cascaded FBG–FPI Hybrid Sensor for Simultaneous Temperature, Pressure, and Humidity Measurement With Sub‐1% Cross‐Sensitivity: A Numerical Design and Simulation Study

Hacen Khlaifi, Amira Zrelli

Journal of Sensors · 2026-01 · 2026 (1)

DOI: 10.1155/js/8331498 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Sensors, online erschienen am 01.11.2026. Verfasst von Hacen Khlaifi und 1 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multiparameter fiber optic sensors face a fundamental challenge: cross‐sensitivity between measured parameters compromises accuracy and limits practical deployment. We present a triple‐cavity cascade architecture combining two fiber Bragg gratings (FBGs) and a Fabry–Pérot interferometer (FPI) for the simultaneous measurement of temperature, pressure, and humidity with exceptional numerically‐predicted discrimination performance. The system exploits complementary sensitivity models in a sensitivity matrix with determinant 2.59 and condition number 644, enabling robust parameter recovery through matrix inversion enhanced by a 3–8–8–3 neural network. A comprehensive numerical simulation over the full operating ranges (0–100°C, 100–500 kPa, 5–95%RH) demonstrates simulated accuracies of ±0.011°C in temperature, ±0.012 kPa in pressure, and ±0.021%RH in humidity, with all six cross‐sensitivity pairs suppressed below 1%. This represents a numerically predicted improvement potential of 5×–15× compared to existing two‐parameter systems and is, to our knowledge, the first numerically demonstrated three‐parameter design based on rigorous theoretical analysis. Error budget analysis identifies coating hysteresis (80%) as the primary accuracy limiter for humidity, while wavelength noise (72%) and phase noise (62%) dominate the temperature and pressure uncertainties, respectively. Dynamic response tests over 100 time steps confirm root mean square error (RMSE) values of 0.071°C, 0.313 kPa, and 0.244%RH under simultaneous sinusoidal, step, and random parameter variations. Although experimental validation remains pending, the rigorous theoretical framework provides a model for next‐generation environmental sensing with applications in aerospace monitoring, industrial process control, and precision instrumentation.

Zitieren

APA

Khlaifi, H., & Zrelli, A. (2026). Triple‐Cavity Cascaded FBG–FPI Hybrid Sensor for Simultaneous Temperature, Pressure, and Humidity Measurement With Sub‐1% Cross‐Sensitivity: A Numerical Design and Simulation Study. Journal of Sensors, 2026(1). https://doi.org/10.1155/js/8331498

Vancouver

Khlaifi H, Zrelli A. Triple‐Cavity Cascaded FBG–FPI Hybrid Sensor for Simultaneous Temperature, Pressure, and Humidity Measurement With Sub‐1% Cross‐Sensitivity: A Numerical Design and Simulation Study. Journal of Sensors. 2026;2026(1). doi:10.1155/js/8331498

BibTeX
@article{Khlaifi2026,
  author = {Khlaifi, Hacen and Zrelli, Amira},
  title = {Triple‐Cavity Cascaded FBG–FPI Hybrid Sensor for Simultaneous Temperature, Pressure, and Humidity Measurement With Sub‐1% Cross‐Sensitivity: A Numerical Design and Simulation Study},
  journal = {Journal of Sensors},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/js/8331498}
}
Kostenlos starten →