EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY 4.0

Performance Evaluation of the Dylos Particulate Matter Sensor: A Systematic Review

Tolulope Elizabeth Aniyikaiye

Journal of Sensors · 2026-01 · 2026 (1)

DOI: 10.1155/js/5542306 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Sensors, online erschienen am 03.07.2026. Verfasst von Tolulope Elizabeth Aniyikaiye. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Low‐cost particulate matter (PM) sensors (LCPMSs) are increasingly used to enhance air quality (AQ) monitoring due to their affordability, portability, and high temporal resolution. Among these devices, the Dylos particle counter has been widely applied in research, indoor monitoring, and community‐based studies; however, evidence of its performance relative to reference‐grade instruments remains dispersed and highly context‐dependent. This systematic review synthesizes and critically evaluates published studies assessing Dylos performance across laboratory, indoor, and field deployments. A structured literature search was conducted across major scientific databases, and eligible studies were examined with respect to calibration strategies, statistical performance metrics, environmental conditions, particle size characteristics, and deployment settings. The reviewed evidence indicates that Dylos generally demonstrates moderate to strong agreement with reference instruments for particle number concentration (PNC) measurements, particularly in indoor environments and under low to moderate PM levels. However, performance varies substantially with calibration approach, aerosol properties, relative humidity (RH), and temporal variability in emissions. Limitations related to its dual‐channel design, passive airflow, and number‐to‐mass conversion constrain reliability in complex or highly dynamic environments. By consolidating fragmented findings, this review clarifies the conditions under which Dylos performs reliably and provides practical guidance for calibration, data interpretation, and future research.

Zitieren

APA

Aniyikaiye, T. E. (2026). Performance Evaluation of the Dylos Particulate Matter Sensor: A Systematic Review. Journal of Sensors, 2026(1). https://doi.org/10.1155/js/5542306

Vancouver

Aniyikaiye TE. Performance Evaluation of the Dylos Particulate Matter Sensor: A Systematic Review. Journal of Sensors. 2026;2026(1). doi:10.1155/js/5542306

BibTeX
@article{Aniyikaiye2026,
  author = {Aniyikaiye, Tolulope Elizabeth},
  title = {Performance Evaluation of the Dylos Particulate Matter Sensor: A Systematic Review},
  journal = {Journal of Sensors},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/js/5542306}
}
Kostenlos starten →