Abstract (Originalsprache)
Induction magnetometers are widely used in weak magnetic field detection applications such as geophysical exploration, space magnetic field measurements, and electromagnetic monitoring. Due to their high sensitivity and wide detection bandwidth, they are considered promising instruments for detecting magnetic anomalies in various environments. Previous experimental studies have reported that electromagnetic emission (EME) and acoustic emission (AE) can occur during rock fracture and material failure processes, which may produce detectable electromagnetic disturbances in the surrounding environment. However, the inherent parasitic inductance and capacitance of the sensing coil lead to pronounced resonance effects, resulting in significant nonlinear distortion in both amplitude–frequency and phase–frequency responses. Classical studies, such as Dehmel (1989), have shown that resistive damping can effectively suppress resonance in search‐coil sensors. Building upon this established framework, this study presents a systematic analysis of resonance suppression strategies, including impedance matching, resistive feedback, and resonant feedback networks. A unified equivalent circuit model of the induction coil is established, and the effects of different feedback architectures on system damping, sensitivity, and phase response are quantitatively evaluated. In particular, the phase–frequency characteristics near resonance are analyzed in detail, providing insights into bandwidth and signal fidelity that are not explicitly addressed in previous studies. The results show that while classical resistive damping remains highly effective, alternative feedback structures introduce additional phase distortion and stability limitations. A combined scheme integrating impedance matching and resistive feedback is shown to provide a favorable trade‐off between resonance suppression, phase linearity, with an average sensitivity of 2.8 mV/nT in the frequency band of 10 Hz–20 kHz. This work provides a comprehensive comparative framework for the design and optimization of resonance suppression circuits in induction magnetometers.
Zitieren
APA
Li, T., Huang, H., & Xiao, X. (2026). Study on Output Resonance Suppression of Inductive Magnetometer. Journal of Sensors, 2026(1). https://doi.org/10.1155/js/3734974
Vancouver
Li T, Huang H, Xiao X. Study on Output Resonance Suppression of Inductive Magnetometer. Journal of Sensors. 2026;2026(1). doi:10.1155/js/3734974
BibTeX
@article{Li2026,
author = {Li, Ting and Huang, Huxing and Xiao, Xiaobing},
title = {Study on Output Resonance Suppression of Inductive Magnetometer},
journal = {Journal of Sensors},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/js/3734974}
}