EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Super‐Hydrophilic TiO 2 Sensor for In Situ pH Measurement in Soilless Cultivation Substrates With Reduced Error and Fast Response

Zhangyong Yu, Jinchao Ma, Yumei Ye, Jisuo Li, Jinlong Liu, Cheng Chen

Journal of Sensors · 2026-01 · 2026 (1)

DOI: 10.1155/js/2553464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Sensors, online erschienen am 14.11.2026. Verfasst von Zhangyong Yu und 5 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Joint Project of Industry-University-Research of Jiangsu Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work evaluates the in situ pH sensing performance of a super‐hydrophilic pH sensor in soilless cultivation substrates, compared with a conventional glass electrode, and analyzes the underlying mechanisms. pH sensors with the super‐hydrophilic TiO 2 sensitive electrode and the Ag/AgCl reference electrode were prepared and characterized by SEM, AFM, and XPS, along with wettability and pH response performance. Soilless substrates of peat, vermiculite, and perlite were prepared with mass water contents (MWCs, θ m ) of 0.2–0.83. The sensors showed maximum deviations from the reference pH (ΔpH) of −0.78 (peat), −0.24 (vermiculite), and −1.14 (perlite) pH units at θ m = 0.2. Compared with the GM, the fabricated sensor achieved comparable deviation levels in water‐saturated substrates, notably exhibiting smaller deviations in substrates with low θ m . The fabricated sensors were substantially faster than the GM across all substrates and moisture conditions, meeting the requirements for rapid in situ pH measurement. The super‐hydrophilicity surface promotes substrate solution spreading, increasing the effective electrode–solution contact area and thereby accelerating electrochemical equilibration at the electrode surface and overcoming low‐moisture limitations. This sensor offers a promising alternative for pH direct measurement (pH‐DM) in soilless cultivation substrates.

Förderung

  • Joint Project of Industry-University-Research of Jiangsu Province

Zitieren

APA

Yu, Z., Ma, J., Ye, Y., Li, J., Liu, J., & Chen, C. (2026). A Super‐Hydrophilic TiO 2 Sensor for In Situ pH Measurement in Soilless Cultivation Substrates With Reduced Error and Fast Response. Journal of Sensors, 2026(1). https://doi.org/10.1155/js/2553464

Vancouver

Yu Z, Ma J, Ye Y, Li J, Liu J, Chen C. A Super‐Hydrophilic TiO 2 Sensor for In Situ pH Measurement in Soilless Cultivation Substrates With Reduced Error and Fast Response. Journal of Sensors. 2026;2026(1). doi:10.1155/js/2553464

BibTeX
@article{Yu2026,
  author = {Yu, Zhangyong and Ma, Jinchao and Ye, Yumei and Li, Jisuo and Liu, Jinlong and Chen, Cheng},
  title = {A Super‐Hydrophilic TiO 2 Sensor for In Situ pH Measurement in Soilless Cultivation Substrates With Reduced Error and Fast Response},
  journal = {Journal of Sensors},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/js/2553464}
}
Kostenlos starten →