EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimization of Electrochemical Aptasensor to Detect Glycated Hemoglobin (HbA1c) as a Diabetes Mellitus Biomarker

Rahmaniar Mulyani, Sheila Destiani, Melania Janisha Devi, Serly Zuliska, Dinda Exelsa Mulyani, Zahra Khira Nafisa, Selvi Apriliana Putri, Toto Subroto, Yeni Wahyuni Hartati, Iman Permana Maksum

Journal of Sensors · 2026-01 · 2026 (1)

DOI: 10.1155/js/1329565 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Sensors, online erschienen am 17.06.2026. Verfasst von Rahmaniar Mulyani und 9 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitas Padjadjaran, Kementerian Riset Teknologi Dan Pendidikan Tinggi Republik Indonesia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glycated hemoglobin (HbA1c), a form of hemoglobin (Hb) bound to glucose, is a widely used biomarker for hyperglycemia, providing diagnostic and monitoring value in diabetes and prediabetes. This study investigated the development of an electrochemical aptasensor for HbA1c detection based on a screen‐printed carbon electrode (SPCE) modified with gold nanoparticles (AuNPs). A biotinylated aptamer was immobilized onto the electrode surface through streptavidin–biotin interaction, and the signal response was evaluated using differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) in the presence of potassium ferricyanide ([K 3 Fe(CN) 6 ]) as a redox probe. The aptasensor response was characterized by a decrease in current upon HbA1c binding. Experimental parameters were systematically examined, and the optimal conditions were obtained at an aptamer concentration of 1.5 µg/mL, an aptamer incubation time of 60 min, and an HbA1c incubation time of 4 min. Under these conditions, the detection limit was 1.17% and the quantification limit was 3.5%, with a dynamic range of 2%–15%. The results indicate that this approach enables sensitive and selective HbA1c detection, supporting its potential application in diabetes diagnosis and monitoring through point‐of‐care (PoC) testing.

Förderung

  • Universitas Padjadjaran
  • Kementerian Riset Teknologi Dan Pendidikan Tinggi Republik Indonesia

Zitieren

APA

Mulyani, R., Destiani, S., Devi, M. J., Zuliska, S., Mulyani, D. E., Nafisa, Z. K., Putri, S. A., Subroto, T., Hartati, Y. W., & Maksum, I. P. (2026). Optimization of Electrochemical Aptasensor to Detect Glycated Hemoglobin (HbA1c) as a Diabetes Mellitus Biomarker. Journal of Sensors, 2026(1). https://doi.org/10.1155/js/1329565

Vancouver

Mulyani R, Destiani S, Devi MJ, Zuliska S, Mulyani DE, Nafisa ZK, et al. Optimization of Electrochemical Aptasensor to Detect Glycated Hemoglobin (HbA1c) as a Diabetes Mellitus Biomarker. Journal of Sensors. 2026;2026(1). doi:10.1155/js/1329565

BibTeX
@article{Mulyani2026,
  author = {Mulyani, Rahmaniar and Destiani, Sheila and Devi, Melania Janisha and Zuliska, Serly and Mulyani, Dinda Exelsa and Nafisa, Zahra Khira and Putri, Selvi Apriliana and Subroto, Toto and Hartati, Yeni Wahyuni and Maksum, Iman Permana},
  title = {Optimization of Electrochemical Aptasensor to Detect Glycated Hemoglobin (HbA1c) as a Diabetes Mellitus Biomarker},
  journal = {Journal of Sensors},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/js/1329565}
}
Kostenlos starten →