EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Combined Utilization of Epithelial Thickness and Tomographic Parameters in Keratoconus Detection

Abdelrahman Salman iD, Mayank Nanavaty iD, Rana Omran iD, Marwan Ghabra iD, Obeda Kailani iD, Rafea Shaaban iD, Taym Darwish iD, Buraa Kubaisi iD, Zein Baradi iD, Mohamed Khallouf iD, Omar Badla iD

Journal of Ophthalmology · 2025-01 · 2025 (1)

DOI: 10.1155/joph/6647993 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Ophthalmology, online erschienen am 18.03.2025. Verfasst von Abdelrahman Salman und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Latakia University, Latakia, Syria. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the performance of the anterior segment optical coherence tomography (AS‐OCT) and Scheimpflug–Placido tomographic (SPT) indices in differentiating suspect keratoconus (SKC) from normal (N).

Methods

In this cross‐sectional study, one eye of each patient was scanned on AS‐OCT and SPT. Following, 5 regression analysis models were developed: Model 1: combined AS‐OCT corneal thickness (CT); Model 2: combined AS‐OCT epithelial thickness (ET); Model 3: Models 1 + 2; Model 4: SPT indices (symmetry index front [SIf], symmetry index back [SIb], keratoconus vertex back [KVb], and minimum CT [ThkMin]); Model 5: Models 3 + 4. The areas under the curve (AUC) of receiver operator characteristic (ROC) curves were compared across groups to estimate their performance accuracy.

Results

Two hundred and five N eyes, 56 SKC eyes, and 89 keratoconus (KC) eyes were scanned with AS‐OCT and SPT. For Models 1 and 2, no individual metric yielded an AUC > 0.84. For Model 3, the AUC was 0.96 (R2 Nagelkerke: 0.69) with 90.28% cases correctly identified as SKC. For Model 4, the AUC was 0.99 (R2 Nagelkerke: 0.87), with 95.58% of cases correctly classified as SKC. For Model 5, the diagnostic accuracy did not improve compared to Model 4.

Conclusion

Both combined AS‐OCT indices and combined SPT indices provided excellent diagnostic power to differentiate SKC from N eyes. The combined SPT model showed a superior value compared to the AS‐OCT model. Furthermore, combined AS‐OCT and SPT data did not perform better than the combined SPT data alone.

Autor:innen und Institutionen

  • Department of Ophthalmology, Latakia University, Latakia, Syria.
  • Syrian Scientific Board of Ophthalmology, Health Ministry, Damascus, Syria.
  • Department of Ophthalmology, University Hospitals Sussex NHS Foundation Trust, London, UK.
  • Department of Cornea, Eye Surgical Hospital, Health Ministry, Damascus, Syria.
  • Department of Ophthalmology, Whipps Cross University Hospital, Leytonstone, London, UK.
  • Department of Ophthalmology, King's College Hospital NHS Foundation Trust, London, UK.

ORCID-Profile: Abdelrahman Salman, Mayank Nanavaty, Rana Omran, Marwan Ghabra, Obeda Kailani, Rafea Shaaban, Taym Darwish, Buraa Kubaisi, Zein Baradi, Mohamed Khallouf, Omar Badla

Zitieren

APA

Salman, A., Nanavaty, M., Omran, R., Ghabra, M., Kailani, O., Shaaban, R., Darwish, T., Kubaisi, B., Baradi, Z., Khallouf, M., & Badla, O. (2025). The Combined Utilization of Epithelial Thickness and Tomographic Parameters in Keratoconus Detection. Journal of Ophthalmology, 2025(1). https://doi.org/10.1155/joph/6647993

Vancouver

Salman A, Nanavaty M, Omran R, Ghabra M, Kailani O, Shaaban R, et al. The Combined Utilization of Epithelial Thickness and Tomographic Parameters in Keratoconus Detection. Journal of Ophthalmology. 2025;2025(1). doi:10.1155/joph/6647993

BibTeX
@article{Salman2025,
  author = {Salman, Abdelrahman and Nanavaty, Mayank and Omran, Rana and Ghabra, Marwan and Kailani, Obeda and Shaaban, Rafea and Darwish, Taym and Kubaisi, Buraa and Baradi, Zein and Khallouf, Mohamed and Badla, Omar},
  title = {The Combined Utilization of Epithelial Thickness and Tomographic Parameters in Keratoconus Detection},
  journal = {Journal of Ophthalmology},
  year = {2025},
  volume = {2025},
  number = {1},
  doi = {10.1155/joph/6647993}
}
Kostenlos starten →