Evaluation of the Homogeneity of Geochemical Reference Materials by Wavelength‐Dispersive X‐Ray Fluorescence Spectrometry Using 0.1 g Fusion Samples
Journal of Chemistry · 2026-01 · 2026 (1)
DOI: 10.1155/joch/3212219 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chemistry, online erschienen am 29.07.2026. Verfasst von Hongkun Zhao und 7 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Major Project, Ministry of Natural Resources of the People's Republic of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Good homogeneity is a critical guarantee for the accuracy of certified reference material values. X‐ray fluorescence spectrometry (XRF) is widely used for the homogeneity testing of geochemical reference materials due to its simple sample preparation and high analytical precision. However, the conventional sample mass required for XRF analysis is relatively large, making its feasibility for small sample sizes controversial. In this study, we customized a Pt–Au crucible with a bottom diameter of 12 mm, matched the XRF sample holder mask to a 12‐mm diameter, and set the view field stop to 10 mm. Meanwhile, the sample preparation and instrumental measurement parameters were comprehensively optimized, and the XRF analysis method based on fusion with a 0.1 g sample size was established. Twelve parallel samples were prepared, and the relative standard deviations (RSDs) were calculated to evaluate the method’s precision. Homogeneity testing of major components was performed on four soil and stream sediment reference materials. For each reference material, 15 bottles were randomly selected to test the between‐bottle homogeneity, and two samples from each bottle were chosen to test the within‐bottle homogeneity. Ten major components (SiO 2 , Al 2 O 3 , TFe 2 O 3 , MgO, CaO, Na 2 O, K 2 O, MnO, TiO 2 , and P 2 O 5 ) were determined, and the data were statistically analyzed using one‐way analysis of variance (ANOVA) F ‐test. The results showed that the RSDs of the fusion method ranged from 0.2% to 6.2%. P 2 O 5 exhibited the maximum RSD of 6.2%, while Na 2 O also presented relatively high RSDs among the measured components. The precision of the proposed method was slightly lower than that of reported methods using conventional sample amounts but superior to those using smaller sample amounts. The F‐test results confirmed that the major components in the four reference materials were homogeneous. This work successfully verifies the feasibility of XRF with a 0.1 g sample size for the homogeneity testing of major components in reference materials with soil and stream sediment matrices, providing a reliable basis for the efficient application of XRF in the development of reference materials.
Förderung
- National Science and Technology Major Project
- Ministry of Natural Resources of the People's Republic of China
- National Natural Science Foundation of China
Zitieren
APA
Zhao, H., Chen, Q., Liu, Y., Zhang, Y., Li, Q., Li, Z., Wang, K., & Yu, Q. (2026). Evaluation of the Homogeneity of Geochemical Reference Materials by Wavelength‐Dispersive X‐Ray Fluorescence Spectrometry Using 0.1 g Fusion Samples. Journal of Chemistry, 2026(1). https://doi.org/10.1155/joch/3212219
Vancouver
Zhao H, Chen Q, Liu Y, Zhang Y, Li Q, Li Z, et al. Evaluation of the Homogeneity of Geochemical Reference Materials by Wavelength‐Dispersive X‐Ray Fluorescence Spectrometry Using 0.1 g Fusion Samples. Journal of Chemistry. 2026;2026(1). doi:10.1155/joch/3212219
BibTeX
@article{Zhao2026,
author = {Zhao, Hongkun and Chen, Qishen and Liu, Yaxuan and Zhang, Yanfei and Li, Qiang and Li, Zhenqing and Wang, Kun and Yu, Qi},
title = {Evaluation of the Homogeneity of Geochemical Reference Materials by Wavelength‐Dispersive X‐Ray Fluorescence Spectrometry Using 0.1 g Fusion Samples},
journal = {Journal of Chemistry},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/joch/3212219}
}
EUVIMED