EUVIMEDEUVIMED entdecken
Multizentrische StudieVergleichsstudieOpen Access · CC BY 4.0

Multicenter Analytical Comparison of Automated Quantitative Assays Versus Line Immunoassay for Anti‐Ro/La Antibody Detection in Primary Sjögren’s Syndrome

Yu-Lan Chen iD, Chao-Jun Hu, Lin-Yi Peng, Dong Xu, Wen Zhang iD, Yan Zhao iD, Dong-Zhou Liu iD, Chinese Sjögren’s Syndrome Collaborative Research Group

Journal of Immunology Research · 2026-01 · 2026 (1)

DOI: 10.1155/jimr/9771858 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Immunology Research, online erschienen am 19.06.2026. Verfasst von Yu-Lan Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rheumatology and Immunology, Shenzhen People's Hospital (The First Affiliated Hospital, Southern University of Science and Technology; …. Hauptthemen laut MEDLINE: Sjogren's Syndrome, Antibodies, Antinuclear. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shenzhen Science and Technology Innovation Program, National Natural Science Foundation of China, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This multicenter study aimed to analytically compare the performance of automated quantitative assays—chemiluminescence immunoassay (CLIA) and multiplexed bead immunoassay (MBI)—for detecting anti‐Ro/La antibodies in Chinese patients with primary Sjögren’s syndrome (pSS), compared to line immunoassay (LIA) that is most commonly used in China.

Methods

Based on the Chinese Sjögren’s Syndrome Collaborative Research Group, serum samples from 434 patients with pSS and 100 healthy controls were analyzed using LIA, CLIA, and MBI. Sensitivity, specificity, and qualitative agreement were assessed. Receiver operating characteristic (ROC) analysis was carried out to compare the analytical accuracy among assays in detecting anti‐Ro/La antibodies, and the DeLong test was used to compare areas under curves (AUCs).

Results

High specificity (95% to 100%) was observed in these assays, and LIA demonstrated the highest sensitivity for anti‐Ro60 (92.6%) and anti‐Ro52 (89.2%). CLIA and MBI exhibited comparable sensitivity to LIA for anti‐La (50.9% vs. 50.2% vs. 48.2%). Qualitative agreement among assays was good for anti‐Ro60 ( κ : 0.84–0.93) and moderate for anti‐La ( κ : 0.74–0.86). MBI achieved the highest AUC values for anti‐Ro60 (0.980), anti‐Ro52 (0.970), and anti‐La (0.935), outperforming CLIA and LIA ( p < 0.05).

Conclusion

Automated assays (CLIA and MBI) demonstrate high specificity and analytical accuracy for anti‐Ro/La antibody detection in pSS. MBI achieved the highest accuracy, whereas LIA showed superior sensitivity for anti‐Ro60/52 detection. CLIA provided reliable specificity but failed to detect anti‐Ro52 in this study. Collectively, these findings indicate that CLIA and MBI may represent reliable alternatives to LIA, although validation in disease‐controlled cohorts is required before clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sjogren's SyndromeAntibodies, AntinuclearHumansFemaleImmunoassayMiddle AgedSensitivity and SpecificityMaleAdultROC CurveLuminescent MeasurementsAgedChinaRibonucleoproteins

Stichwörter der Autor:innen

Sjögren’s syndromechemiluminescence assaydiagnostic performanceline immunoassaymultiplexed bead immunoassay

Substanzen

Antibodies, AntinuclearSS-A antibodiesRibonucleoproteins

Autor:innen und Institutionen

  • Department of Rheumatology and Immunology, Shenzhen People's Hospital (The First Affiliated Hospital, Southern University of Science and Technology; The Second Clinical Medical College, Jinan University), Shenzhen, 5180…
  • Department of Rheumatology, Peking Union Medical College Hospital, Key Laboratory of Rheumatology and Clinical Immunology, Ministry of Education, Peking Union Medical College and Chinese Academy of Medical Sciences, Bei…
  • National Clinical Research Center for Dermatologic and Immunologic Diseases (NCRC-DID), Beijing, 100730, China.

ORCID-Profile: Yu-Lan Chen, Wen Zhang, Yan Zhao, Dong-Zhou Liu

Förderung

  • Shenzhen Science and Technology Innovation Program
  • National Natural Science Foundation of China
  • National Key Research and Development Program of China
  • Chinese Academy of Medical Sciences Initiative for Innovative Medicine

Zitieren

APA

Chen, Y. L., Hu, C. J., Peng, L. Y., Xu, D., Zhang, W., Zhao, Y., Liu, D. Z., & Chinese Sjögren’s Syndrome Collaborative Research Group (2026). Multicenter Analytical Comparison of Automated Quantitative Assays Versus Line Immunoassay for Anti‐Ro/La Antibody Detection in Primary Sjögren’s Syndrome. Journal of Immunology Research, 2026(1). https://doi.org/10.1155/jimr/9771858

Vancouver

Chen YL, Hu CJ, Peng LY, Xu D, Zhang W, Zhao Y, et al. Multicenter Analytical Comparison of Automated Quantitative Assays Versus Line Immunoassay for Anti‐Ro/La Antibody Detection in Primary Sjögren’s Syndrome. Journal of Immunology Research. 2026;2026(1). doi:10.1155/jimr/9771858

BibTeX
@article{Chen2026,
  author = {Chen, Yu-Lan and Hu, Chao-Jun and Peng, Lin-Yi and Xu, Dong and Zhang, Wen and Zhao, Yan and Liu, Dong-Zhou and Chinese Sjögren’s Syndrome Collaborative Research Group, Chinese Sjögren’s Syndrome Collaborative Research Group},
  title = {Multicenter Analytical Comparison of Automated Quantitative Assays Versus Line Immunoassay for Anti‐Ro/La Antibody Detection in Primary Sjögren’s Syndrome},
  journal = {Journal of Immunology Research},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/jimr/9771858}
}
Kostenlos starten →