EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of X‐V Baffle Parameters on Flow and Thermal Characteristics in a Circular Tube Heat Exchanger: A Numerical Study

Amnart Boonloi, Withada Jedsadaratanachai

Journal of Engineering · 2026-01 · 2026 (1)

DOI: 10.1155/je/9265763 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Engineering, online erschienen am 06.11.2026. Verfasst von Amnart Boonloi und 1 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Mongkut's University of Technology North Bangkok.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research emphasizes the effect of varying the flow attack angle ( α = 45 ° , 60°, and 75°) of the X‐V baffle employed for heat transfer (H‐T) enhancement in a circular tube heat exchanger (H‐X). A numerical approach was adopted to gain a deeper understanding of the fluid flow (F‐F) behavior and thermal structure developed within the tested system. The blockage ratio of the X‐V baffle was varied in the range of 0.05–0.30 ( b / D = B − K = 0.05 − 0.30), whereas the pitch ratio was selected as 1, 1.5, and 2 ( P / D = P − T = 1, 1.5, and 2). The tested fluid was air. The analysis was conducted under turbulent flow conditions with Reynolds numbers (based on inlet conditions) ranging from 3000 to 16,000. Both flow directions (FDT), namely, +x FDT and −x FDT, were considered in the investigation. The finite volume method (FVM) implemented in a reliable and accurate commercial computational package was employed for the present study. The model development and validation procedures were appropriately designed and systematically conducted. The results revealed that variations in the flow attack angle significantly affected the H‐T rate as well as the overall thermal enhancement performance. The maximum thermal performance in terms of thermal enhancement factor (TE‐F) obtained in this studied test was 2.13, which was achieved at the flow attack angle of 45°.

Förderung

  • King Mongkut's University of Technology North Bangkok

Zitieren

APA

Boonloi, A., & Jedsadaratanachai, W. (2026). Influence of X‐V Baffle Parameters on Flow and Thermal Characteristics in a Circular Tube Heat Exchanger: A Numerical Study. Journal of Engineering, 2026(1). https://doi.org/10.1155/je/9265763

Vancouver

Boonloi A, Jedsadaratanachai W. Influence of X‐V Baffle Parameters on Flow and Thermal Characteristics in a Circular Tube Heat Exchanger: A Numerical Study. Journal of Engineering. 2026;2026(1). doi:10.1155/je/9265763

BibTeX
@article{Boonloi2026,
  author = {Boonloi, Amnart and Jedsadaratanachai, Withada},
  title = {Influence of X‐V Baffle Parameters on Flow and Thermal Characteristics in a Circular Tube Heat Exchanger: A Numerical Study},
  journal = {Journal of Engineering},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/je/9265763}
}
Kostenlos starten →