Fachartikel in der Zeitschrift Journal of Analytical Methods in Chemistry, online erschienen am 20.05.2026. Verfasst von Tesfamichael Gebretsadikan und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmacy, College of Health Sciences, Mekelle University, P.O. Box 1871, Mekelle, Tigray, Ethiopia, mu.edu.et. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Potassium bromate (KBrO 3 ) is a flour additive that strengthens dough and increases bread volume. However, the International Agency for Research on Cancer (IARC) has labeled it as a possible human carcinogen. Despite being banned in many countries, KBrO 3 is still found in bread, particularly in resource‐limited settings like Ethiopia, which can pose serious health risks. Objective of Study The goal of this study is to develop and validate a sensitive, selective, and accurate high‐performance liquid chromatography (HPLC) method for detecting and measuring KBrO 3 in bread using a quality by design (QbD) approach. Methodology A reverse‐phase HPLC method was developed and optimized using the central composite design (CCD) expert. Chromatographic analysis was performed on a C18 column with a mobile phase consisting of acetonitrile and phosphate buffer. The method was validated following the ICH Q2(R1) guidelines. Fifteen commercial bread samples were collected from each subcity of Mekelle and analyzed using the developed method.
Results
The developed method demonstrated excellent linearity, precision, and accuracy, with recovery rates between 96% and 99%. The limit of detection (LOD) was 0.015 mg/kg. Bromate residues were detected in all bread samples, with concentrations ranging from 4.5 to 9.15 mg/kg, which is significantly higher than the WHO/FDA safety limit of 0.02 mg/kg.
Conclusion
The validated HPLC method provides a reliable and accurate tool for routine monitoring of KBrO 3 in bread. The results highlight significant public health risks associated with excessive bromate use in local bread production and call attention to the urgent need for strengthened regulatory controls and enforcement of food safety standards in Ethiopia.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Pharmacy, College of Health Sciences, Mekelle University, P.O. Box 1871, Mekelle, Tigray, Ethiopia, mu.edu.et.
- Department of Chemistry, College of Natural and Computational Sciences, Mekelle University, P.O. Box 231, Mekelle, Tigray, Ethiopia, mu.edu.et.
ORCID-Profile: Tesfamichael Gebretsadikan, Mebrahtom Gebrelibanos Hiben, Kalayou Hiluf Gebremedhin, Teklu Hailu Abay
Zitieren
APA
Gebretsadikan, T., Hiben, M. G., Gebremedhin, K. H., Zebrehe, M., Fisseha, H., & Abay, T. H. (2026). High‐Performance Liquid Chromatography Method Optimization and Validation for Potassium Bromate Detection in Bread Using a Quality‐by‐Design Approach. Journal of Analytical Methods in Chemistry, 2026(1). https://doi.org/10.1155/jamc/9966003
Vancouver
Gebretsadikan T, Hiben MG, Gebremedhin KH, Zebrehe M, Fisseha H, Abay TH. High‐Performance Liquid Chromatography Method Optimization and Validation for Potassium Bromate Detection in Bread Using a Quality‐by‐Design Approach. Journal of Analytical Methods in Chemistry. 2026;2026(1). doi:10.1155/jamc/9966003
BibTeX
@article{Gebretsadikan2026,
author = {Gebretsadikan, Tesfamichael and Hiben, Mebrahtom Gebrelibanos and Gebremedhin, Kalayou Hiluf and Zebrehe, Mulaynesh and Fisseha, Hayelom and Abay, Teklu Hailu},
title = {High‐Performance Liquid Chromatography Method Optimization and Validation for Potassium Bromate Detection in Bread Using a Quality‐by‐Design Approach},
journal = {Journal of Analytical Methods in Chemistry},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/jamc/9966003}
}
EUVIMED