EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rapid Detection of Tetracycline Residues in Milk Using Colorimetric Sensor Based on Polymethylmethacrylate (PMMA) and Polystyrene (PS) Polymers

Rimadani Pratiwi iD, Putri Nur Azizah, Aliya Nur Hasanah iD

Journal of Analytical Methods in Chemistry · 2026-01 · 2026 (1)

DOI: 10.1155/jamc/5412774 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Analytical Methods in Chemistry, online erschienen am 20.05.2026. Verfasst von Rimadani Pratiwi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Sumedang, 45363, Indonesia, unpad.ac.id. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 96 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, the colorimetric approach is applied on an indicator strip for tetracycline detection in milk residue. Indicator strips made from PMMA‐concentrated H 2 SO 4 (9:1), PMMA‐Mecke (9:1), and PMMA‐Marquis (9:1) are the best compositions that can detect tetracycline within 10 s. The test results using scanning electron microscopy–energy‐dispersive X‐ray spectroscopy (SEM‐EDS) and infrared spectrophotometer showed that the reagent had entered the PMMA‐based indicator strip. The limit of quantification (LOQ) and limit of detection (LOD) were 11.64 ppm and 3.49 ppm, respectively. The indicator strip has high selectivity toward tetracycline and is stable for 60 days at room temperature in a desiccator. The indicator strip detects tetracycline in milk samples with an accuracy of 83.24%–99.66%. The accuracy test results using liquid chromatography–tandem mass spectrometry (LC‐MS/MS) also observed. The indicator strip may be appropriate as an initial screening tool for high‐level tetracycline contamination; however, its utility is limited for purposes of strict regulatory compliance.

Schlagwörter

Stichwörter der Autor:innen

PMMAPScolorimetric sensorindicator strippolymertetracycline

Autor:innen und Institutionen

  • Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Sumedang, 45363, Indonesia, unpad.ac.id.

ORCID-Profile: Rimadani Pratiwi, Aliya Nur Hasanah

Zitieren

APA

Pratiwi, R., Azizah, P. N., & Hasanah, A. N. (2026). Rapid Detection of Tetracycline Residues in Milk Using Colorimetric Sensor Based on Polymethylmethacrylate (PMMA) and Polystyrene (PS) Polymers. Journal of Analytical Methods in Chemistry, 2026(1). https://doi.org/10.1155/jamc/5412774

Vancouver

Pratiwi R, Azizah PN, Hasanah AN. Rapid Detection of Tetracycline Residues in Milk Using Colorimetric Sensor Based on Polymethylmethacrylate (PMMA) and Polystyrene (PS) Polymers. Journal of Analytical Methods in Chemistry. 2026;2026(1). doi:10.1155/jamc/5412774

BibTeX
@article{Pratiwi2026,
  author = {Pratiwi, Rimadani and Azizah, Putri Nur and Hasanah, Aliya Nur},
  title = {Rapid Detection of Tetracycline Residues in Milk Using Colorimetric Sensor Based on Polymethylmethacrylate (PMMA) and Polystyrene (PS) Polymers},
  journal = {Journal of Analytical Methods in Chemistry},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/jamc/5412774}
}
Kostenlos starten →