Dynamic and Predictive Modeling of Indoor CO 2 Concentration and Its Impact on Energy Consumption in Educational Buildings
Indoor Air · 2026-01 · 2026 (1)
DOI: 10.1155/ina/4441388 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indoor Air, online erschienen am 20.08.2026. Verfasst von Ali Maboudi Reveshti und 1 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Indoor CO 2 concentration in educational buildings serves as both an indicator of ventilation adequacy and a direct driver of HVAC energy demand. Yet, these two dimensions are rarely examined within a single integrated framework. This study proposes such a framework, combining four coupled components: a whole‐building EnergyPlus thermal model of a Mechanical Engineering faculty building (benchmarked against published data rather than calibrated with measured energy data), a physics‐based mass balance CO 2 model driven by hourly occupancy and ventilation outputs from EnergyPlus, a long short‐term memory (LSTM) network for predictive CO 2 forecasting, and a systematic six‐category multiscenario energy analysis. The mass balance model reproduces peak classroom CO 2 concentrations of 1200–1300 ppm during full occupancy, exceeding the ASHRAE 1000‐ppm threshold, and recovers to near‐outdoor levels within 20–40 min after occupancy ends. The LSTM model delivers 1‐h‐ahead CO 2 forecasts with RMSE = 42 ppm and R 2 = 0.94, outperforming persistence ( R 2 = 0.71), linear regression ( R 2 = 0.88), and gradient boosting ( R 2 = 0.92) baselines, with its largest advantage occurring during occupancy transitions. The six‐category energy scenario analysis identifies HVAC schedule optimization (17%–22% annual savings), advanced double‐pane LowE/LowER glazing (~10%), and reduced window area (~7%) as the most impactful interventions. Under the idealized IdealLoadsAirSystem representation, the fully optimized configuration cuts annual building energy consumption by 34% (30% in winter, 40% in summer), with ±5–7 percentage points of combined uncertainty; real HVAC systems would likely realize smaller savings due to equipment efficiency and control dynamics. Overall, the framework establishes a conceptual and methodological basis for future LSTM‐driven demand‐controlled ventilation (DCV) strategies in educational buildings. However, no closed‐loop control algorithm was implemented or tested here.
Zitieren
APA
Reveshti, A. M., & Maroofiazar, R. (2026). Dynamic and Predictive Modeling of Indoor CO 2 Concentration and Its Impact on Energy Consumption in Educational Buildings. Indoor Air, 2026(1). https://doi.org/10.1155/ina/4441388
Vancouver
Reveshti AM, Maroofiazar R. Dynamic and Predictive Modeling of Indoor CO 2 Concentration and Its Impact on Energy Consumption in Educational Buildings. Indoor Air. 2026;2026(1). doi:10.1155/ina/4441388
BibTeX
@article{Reveshti2026,
author = {Reveshti, Ali Maboudi and Maroofiazar, Rasool},
title = {Dynamic and Predictive Modeling of Indoor CO 2 Concentration and Its Impact on Energy Consumption in Educational Buildings},
journal = {Indoor Air},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/ina/4441388}
}
EUVIMED