Evaluation of the Trueness and Precision of a Simplified Method for Transferring the Relationship of the Maxillary Plane and Transverse Hinge Axis to Virtual Articulators
International Journal of Dentistry · 2026-01 · 2026 (1)
DOI: 10.1155/ijod/2778184 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Dentistry, online erschienen am 05.06.2026. Verfasst von Chaimongkon Peampring und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Hat Yai, 90110, Thailand, psu.ac.th. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The digital transfer of data for establishing the maxillary occlusal plane and condylar path aims for high precision, facilitating accurate use of virtual articulators and aiding in digital prosthetic fabrication.
Objective
This study evaluates the accuracy of transferring maxillary scans to a virtual articulator using a novel customized transfer tool compared to a conventional facebow system.
Methods
Three types of master models, bilateral balanced, monoplane, and lingualized occlusion, were prepared and duplicated. Landmarks on the maxillary and mandibular models were identified, and interlandmark distances served as controls. The models were scanned intraorally, and virtual bite alignment was performed using a best‐fit algorithm. A manual facebow transfer defined the occlusal and condylar relationships on a mechanical articulator, which was then transferred to a virtual articulator via the customized transfer tool and computer‐aided design (CAD) software. Transfer accuracy was assessed by comparing interlandmark distances between mechanical and virtual setups using statistical tests (Shapiro–Wilk, Levene’s, and t ‐tests) at α = 0.05. Reliability was evaluated with the intraclass correlation coefficient (ICC).
Results
No significant differences were found between the mechanical and virtual interlandmark distances across all models ( p > 0.05). Differences ranged from −0.08 to 0.11 mm, within clinically acceptable limits. ICC values exceeded 0.80, indicating high reliability of the transfer method.
Conclusions
The customized transfer tool accurately transferred maxillary occlusal plane and condylar path relationships to the virtual articulator, with no significant discrepancies observed.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Hat Yai, 90110, Thailand, psu.ac.th.
- Galyanivadhanakarun Hospital, Princess of Naradhiwas University, Khok Khian, Mueang Narathiwat District, Narathiwat, 96000, Thailand, pnu.ac.th.
ORCID-Profile: Chaimongkon Peampring, Leena Kiratiwudh
Zitieren
APA
Peampring, C., & Kiratiwudh, L. (2026). Evaluation of the Trueness and Precision of a Simplified Method for Transferring the Relationship of the Maxillary Plane and Transverse Hinge Axis to Virtual Articulators. International Journal of Dentistry, 2026(1). https://doi.org/10.1155/ijod/2778184
Vancouver
Peampring C, Kiratiwudh L. Evaluation of the Trueness and Precision of a Simplified Method for Transferring the Relationship of the Maxillary Plane and Transverse Hinge Axis to Virtual Articulators. International Journal of Dentistry. 2026;2026(1). doi:10.1155/ijod/2778184
BibTeX
@article{Peampring2026,
author = {Peampring, Chaimongkon and Kiratiwudh, Leena},
title = {Evaluation of the Trueness and Precision of a Simplified Method for Transferring the Relationship of the Maxillary Plane and Transverse Hinge Axis to Virtual Articulators},
journal = {International Journal of Dentistry},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/ijod/2778184}
}
EUVIMED