EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Hybrid PCF‐SPR Sensor for Electrolyte Sensing Using Finite Element Method and Machine Learning

Nayan Roy, Sourov Das, Shahriar Amin, Hasan Sarker

International Journal of Optics · 2026-01 · 2026 (1)

DOI: 10.1155/ijo/6447280 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Optics, online erschienen am 17.11.2026. Verfasst von Nayan Roy und 3 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research presents a novel PCF‐SPR sensor with a dual‐sensing mechanism that allows both internal and external sensing in a single fiber. Since the internal and external regions detect two separate analytes independently, the sensor is well suited for hybrid sensing. This is made possible by a gold film that is uniformly coated on the outer surface of the fiber and on the outer wall of the internal analyte channel, and it excites the surface plasmon resonance (SPR) effect. The sensor shows strong performance over a broad refractive index range, covering 1.26–1.34 for internal sensing and 1.33–1.41 for external sensing. All simulations were performed using the finite element method (FEM) in COMSOL Multiphysics 6.1a. The optimized sensor achieves maximum wavelength sensitivities of 10,000 nm/RIU (internal) and 3000 nm/RIU (external) and maximum amplitude sensitivities of −677.56 RIU −1 (internal) and −86.39 RIU −1 (external). The minimum sensor resolutions (SRs) are 1.00 × 10 −5 RIU (internal) and 3.33 × 10 −5 RIU (external), and the figures of merit (FOMs) are 166.62 RIU −1 (internal) and 15.87 RIU −1 (external). To evaluate the hybrid sensing performance, two electrolytes, KCl and CaCl 2 , were used as representative analytes, with wavelength sensitivities of 1937.98 nm/RIU and 8000 nm/RIU, respectively. Finally, machine learning models were applied to predict the confinement loss. Support vector regression (SVR) performed best ( R 2 = 0.999, RMSE = 0.032, and MAE = 0.0206, MAPE = 1.230%), confirming the strong sensing potential of the proposed sensor.

Zitieren

APA

Roy, N., Das, S., Amin, S., & Sarker, H. (2026). A Hybrid PCF‐SPR Sensor for Electrolyte Sensing Using Finite Element Method and Machine Learning. International Journal of Optics, 2026(1). https://doi.org/10.1155/ijo/6447280

Vancouver

Roy N, Das S, Amin S, Sarker H. A Hybrid PCF‐SPR Sensor for Electrolyte Sensing Using Finite Element Method and Machine Learning. International Journal of Optics. 2026;2026(1). doi:10.1155/ijo/6447280

BibTeX
@article{Roy2026,
  author = {Roy, Nayan and Das, Sourov and Amin, Shahriar and Sarker, Hasan},
  title = {A Hybrid PCF‐SPR Sensor for Electrolyte Sensing Using Finite Element Method and Machine Learning},
  journal = {International Journal of Optics},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/ijo/6447280}
}
Kostenlos starten →